OPERATOR'S MANUAL MODEL #201110 9200W ELECTRIC START GENERATOR REGISTER YOUR PRODUCT ONLINE at championpowerequipment.com or visit championpowerequipment.com SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do so could result in serious injury. This manual should remain with the product.
CARBON MONOXIDE SAFETY: THE BIG PICTURE CARBON MONOXIDE K ILLS MANUAL As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect your family from this colorless, oderless threat.
Table of Contents 201110 - 9200W Electric Start Generator TABLE OF CONTENTS Maintenance................................................. 25 Cleaning the Generator........................................... 26 Introduction.................................................... 4 Changing the Engine Oil.......................................... 26 Safety Definitions........................................... 4 Cleaning and Adjusting the Spark Plug................. ..........
Introduction 201110 - 9200W Electric Start Generator INTRODUCTION SAFETY DEFINITIONS Congratulations on your purchase of a Champion Power Equipment (CPE) product. CPE designs, builds, and supports all of our products to strict specifications and guidelines. With proper product knowledge, safe use, and regular maintenance, this product should bring years of satisfying service. The purpose of safety symbols is to attract your attention to possible dangers.
Important Safety Instructions 201110 - 9200W Electric Start Generator IMPORTANT SAFETY INSTRUCTIONS DANGER Operate equipment with guards in place. WARNING Rotating parts can entangle hands, feet, hair, clothing and/or accessories. Traumatic amputation or severe laceration can result. Cancer and Reproductive Harm – www.P65Warnings.ca.gov DANGER Keep hands and feet away from rotating parts. Generator exhaust contains carbon monoxide, a colorless, odorless, poisonous gas.
Important Safety Instructions 201110 - 9200W Electric Start Generator CAUTION WARNING Spark from removed spark plug wire can result in fire or electrical shock. Exceeding the generator’s running capacity can damage the generator and/or electrical devices connected to it. When servicing the generator: DO NOT overload the generator. Disconnect the spark plug wire and place it where it cannot contact the plug or any other metal object. DO NOT tamper with the governed speed.
Important Safety Instructions 201110 - 9200W Electric Start Generator Fuel Safety When operating the generator: DO NOT move or tip the generator during operation. DANGER When transporting or servicing the generator: GASOLINE AND GASOLINE VAPORS ARE HIGHLY FLAMMABLE AND EXPLOSIVE. Always check that the fuel valve is in the OFF position and the gasoline tank is empty. Fire or explosion can cause severe burns or death.
Important Safety Instructions 201110 - 9200W Electric Start Generator Safety and Dataplate Labels These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement. E D A B C Top Back Side LABEL A DESCRIPTION Safety Symbols/ CO Danger 1028-L-SF-E DANGER PELIGRO DANGER Using a generator indoors CAN KILL YOU IN MINUTES.
Important Safety Instructions 201110 - 9200W Electric Start Generator Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product. SYMBOL MEANING Read Operator’s Manual. To reduce the risk of injury, user must read and understand operator’s manual before using this product. Clearance. Keep all objects at least 5 feet (1.5m) from generator.
Important Safety Instructions 201110 - 9200W Electric Start Generator Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
Important Safety Instructions 201110 - 9200W Electric Start Generator Quickstart Label Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product. 2 3 4 5 6 7 8 1 2 3 1 10W-30 3 3124-L-OP-A Starting the Engine DANGER Colors Stopping the Engine APN 3124-L-OP Rev A Size 243 x 35 mm Artwork Notes 1.
Controls and Features 201110 - 9200W Electric Start Generator CONTROLS AND FEATURES Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator 1 3 2 14 4 13 5 6 11 7 9 8 10 12 1. Gasoline Tank – 7.7 gal. (29.1 L) 10. Support Leg 2. Gasoline Gauge 11. Battery – Provides 12V DC power the starting system. 3. Fuel Cap – Remove to add fuel. 12.
Controls and Features 201110 - 9200W Electric Start Generator Control Panel 1 2 3 A 5 4 C 5 B 1. Ignition Switch – Used to START or STOP the generator. RECEPTACLES 2. Intelligauge – Four mode digital meter for displaying voltage, frequency, run time, and total run time. A 3. CO Shield® LED – The CO Shield® technology monitors for accumulation of poisonous carbon monoxide (CO) gas produced by engine exhaust when the generator is running.
Controls and Features 201110 - 9200W Electric Start Generator Intelligauge Four mode digital meter for displaying voltage, frequency, run time, and total run time. Multi-colored LED indicated CO shutoff or fault. MODE DESCRIPTION Output voltage of the generator. Voltage (V) Example: 120 volts Output frequency in hertz. Frequency (H) Example: 60.
Controls and Features 201110 - 9200W Electric Start Generator Parts Included Accessories Engine Oil...................................... 37.2 fl. oz. (1100 ml) Oil Funnel............................................................ 1 Assembly Parts Wheels 9.5 in. (24.1 cm) Never Flat Wheel (A).......................... 2 Wheel Hub Cap (B)............................................... 2 Roll Pin (C)....................................................... 2 Large R-clip (D)..................................
Assembly 201110 - 9200W Electric Start Generator ASSEMBLY Install the Support Leg Your generator requires some assembly. It must be properly serviced with fuel and oil before operation. 1. Attach the support leg (E) to the generator frame with flange bolts (F) and flange lock nuts (G). If you have any questions regarding the assembly of your generator, call our Technical Support Team at 1-877-338-0999. Please have your serial number and model number available. 2.
Assembly 201110 - 9200W Electric Start Generator NOTICE NOTICE The recommended oil type for typical use is 10W-30 automotive oil. However, using the listed conventional oils shown in the “Recommended Engine Oil Type” chart may be used for typical use including the first 5 hours of the break-in run time period of the engine. Once oil has been added, a visual check should show oil about 1-2 threads from running out of the fill hole.
Assembly 201110 - 9200W Electric Start Generator Use clean, fresh, regular unleaded gasoline with a minimum octane rating of 87 and an ethanol content of 10% or less by volume. y b c CAUTION Use unleaded gasoline with a minimum octane rating of 87 and an ethanol content of 10% or less by volume. DO NOT mix oil with gasoline. 1. Remove the gasoline cap. DO NOT light cigarettes or smoke when filling the tank. 2. Slowly add gasoline to the tank. Tank is full when gasoline reaches red circle on screen.
Operation 201110 - 9200W Electric Start Generator Grounding Your generator must be properly connected to an appropriate ground to help prevent electric shock. WARNING Failure to properly ground the generator can result in electric shock.
Operation 201110 - 9200W Electric Start Generator Generator Location NOTICE WARNING This blinking does not indicate CO Shield is working, as CO Shield is working at all times the generator is running. Also, the LED will not blink (10) times if the generator was restarted within 1 minute after it was manually shut off. This does not SHUTOFF occur if generator shut off from a high CO event.
Operation 201110 - 9200W Electric Start Generator Electric Start WARNING 1. Move the choke lever to the “CHOKE” position. Do not expose to rain or use in damp locations. 1a. For restarting a warm engine, move the choke lever to 75% of the “CHOKE” position. Keep all objects a minimum of 5 feet (1.5m) away from the generator at all times. Heat from the muffler surface and exhaust gas stream can ignite combustible materials.
Operation 201110 - 9200W Electric Start Generator Manual Start 1. Push the ignition switch to the “ON” position. 4. Do not over-choke. As soon as engine starts, move the choke lever to the “RUN” position over a 2-5 second duration. 2. Move the choke lever to the “CHOKE” position. NOTICE Keep choke lever in “CHOKE” position for only 1 pull of the recoil cord. After first pull, move choke lever to “RUN” position for up to 3 pulls of the recoil cord.
Operation 201110 - 9200W Electric Start Generator Battery Do Not Overload Generator Capacity NOTICE Follow these simple steps to calculate the running and starting watts necessary for your purposes: The supplied 12V battery does re-charge while the engine is running, but it is also recommended that the battery be fully charged at least once per month or maintained with a trickle charger or battery maintainer (not included). 1. Select the electrical devices you plan on running at the same time. 2.
Operation 201110 - 9200W Electric Start Generator Stopping the Engine To ensure proper operation of the GFCI duplex, perform this test monthly: 1. Turn off and unplug all connected electrical loads. Never start or stop the generator with electrical devices plugged in or turned on. 1. With the generator running, plug a lamp into the GFCI receptacle. Turn the lamp on. 2. Press the “TEST” (C) button located on the front of the receptacle to trip the device.
Maintenance 201110 - 9200W Electric Start Generator Moving the Generator To alleviate high altitude issues other than the natural power loss, CPE can provide a high altitude carburetor main jet. The alternative main jet and installation instructions can be obtained by contacting our Technical Support Team. Installation instructions are also available in the Technical Bulletin area of the CPE website. CAUTION – NEVER lift or carry the generator using the folding handle.
Maintenance 201110 - 9200W Electric Start Generator The owner/operator is responsible for all periodic maintenance. 3. Replace the oil drain bolt. Complete all scheduled maintenance in a timely manner. Correct any issue before operating the generator. 4. Add oil according to Add Engine Oil in Assembly section. DO NOT OVERFILL. Oil not included for routine maintenance. For service or parts assistance, contact our Technical Support Team at 1-877-338-0999. 5.
Maintenance 201110 - 9200W Electric Start Generator Cleaning the Air Filter CAUTION 1. Remove the snap-on cover holding the air filter to the assembly. Failure to clean the spark arrestor will result in degraded engine performance. NOTICE Federal and local laws and administrative requirements indicate when and where spark arrestors are required. When ordered, spark arrestors are required for operation of this generator in National Forest lands.
Storage 201110 - 9200W Electric Start Generator Disconnect the Battery EVERY 100 HOURS OR ANNUALLY 1. Pull two halves of battery connector apart. Change oil Clean/adjust spark plug Clean spark arrestor Clean fuel valve filter* EVERY 250 HOURS Clean combustion chamber* Check/adjust valve clearance* EVERY 3 YEARS Replace fuel line* Charge the Battery * To be performed by knowledgeable, experienced owners or CPE certified service centers.
Storage 201110 - 9200W Electric Start Generator Long Term Storage (over 1 year) 4. Start and run the generator for 10 minutes so the treated gasoline cycles through the fuel system. For storage over 1 year, the gasoline tank and carburetor must be completely drained of gasoline. 5. Option 1: Drain Gasoline from Carburetor 5a. Turn ignition switch to the “OFF” position and allow generator to cool completely before continuing. 1. The generator is to be OFF and all appliances disconnected. 2.
Specifications 201110 - 9200W Electric Start Generator SPECIFICATIONS Recommended Engine Oil Type 10W-30 Generator Specifications 5W-30 Generator Model............................................ 201110 10W-40 5W-30 Full Synthetic Start Type.......................................... Electric, Manual °F -20 °C -28.9 Watts (Starting/Running).............................. 11500/9200 AC Volts. . .................................................... 120/240 0 -17.8 20 -6.7 40 4.4 60 15.6 80 26.
Troubleshooting 201110 - 9200W Electric Start Generator TROUBLESHOOTING Problem Cause Solution No fuel. Add fuel. Faulty spark plug. Clean and adjust spark plug or replace. Fill crankcase to the proper level. Low oil level. Engine will not start. Place generator on a flat, level surface. Spark plug wire loose. Attach wire to spark plug. Fuel valve is closed. Open fuel valve. Ignition switch OFF. Press ignition switch ON. Old fuel or water in fuel. Drain fuel and replace with fresh fuel.
Troubleshooting 201110 - 9200W Electric Start Generator Problem Engine is running but no AC output. Engine hunts or falters. Repeated circuit breaker tripping. Cause Solution Poor cord connection. Check all connections. Circuit breaker is open. Reset circuit breaker. Check all circuit breakers. Faulty brush assembly. Replace brush assembly (Service Center). Loose wiring. Inspect and tighten wiring connections. GFCI tripped.
WARRANTY* Other Exclusions CHAMPION POWER EQUIPMENT 3 YEAR LIMITED WARRANTY This warranty excludes: Warranty Qualifications To register your product for warranty and FREE lifetime call center technical support please visit: https://www.championpowerequipment.com/register To complete registration you will need to include a copy of the purchase receipt as proof of original purchase. Proof of purchase is required for warranty service. Please register within ten (10) days from date of purchase.
CHAMPION POWER EQUIPMENT, INC. (CPE), THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (U.S. EPA) AND THE CALIFORNIA AIR RESOURCES BOARD (CARB) EMISSION CONTROL SYSTEM WARRANTY Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air Resources Board (CARB) Exhaust and Evaporative emissions regulations.
EXHAUST AND EVAPORATIVE EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Exhaust and Evaporative Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (SORE) (for other states, 1997 and later model year engines).
EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the engine) Systems covered by this warranty Parts Description Fuel Metering System Carburetor and internal parts (and/or pressure regulator or fuel injection system), Air/fuel ratio feedback and control system, Cold start enrichment system. Air Induction System Controlled hot air intake system, Intake manifold, Air filter.