User's Manual

27
Digital Display
Display Meter Operation Checks
Check the Meter LEDs:
1. Turn the Dishwasher Power Switch ON. The 3-digit LEDs illuminate simultaneosly, the each LED
bar illuminates from left-to-right.
Check the Meter Temperature Set-point:
Refer to the photo below and the "Rear view of the Digital Displat Circuit Board" on the next page.
1. Remove the top-mounted control cabinet panel. Locate the CHECK pushbutton on the rear of
the display. The pushbutton is located at the top and center of the board.
2. There are 6 set-point values: 70, 120, 150, 160, 165, and 180°F.
3. Turn the dishwasher Power Switch ON, then Push and Hold the CHECK pushbutton. Meter 1
flashes the current user-defined set-point. Meter 2 is blank.
4. Continue to Hold the CHECK pushbutton. Meter 1 blanks out and Meter 2 flashes its current
set-point value of 70, 120, 150, 160, 165, and 180°F.
5. Release the CHECK button. Meter 1 and Meter 2 display the actual temperatures in the wash
tanks.
6. A final rinse Meter will dislay OFF until the final rinse switch is activated, then the meter
displays the actual final rinse temperature which is measured at the final rinse manifold.
Check the Meter Temperature Set-point:
The set-point determines how the meter displays the yellow and green bar. For example, if the set-
point is 70, then the bar displays yellow from 0-70, then green from 70 and above.
1. Push and Hold the CHECK oushbutton until Meter 1 display flashes.
2. Release the CHECK pushbutton. Meter 1 goes through the set-point values each time the
CHECK pushbutton is pushed and released. The set-point value advances from 70, 120, 150,
160, 165, and 180°F.
3. When the new set-point appeats on the display, hold the CHECK pushbutton until the display
flashes. The number that is displayed is the new-set-point. If the display advances past the
desired set-point, repeat Steps 1-2.
4. In order to change Meter 2, Push and Hold the CHECK pushbutton until Meter 1 flashes.
Continue to Hold the CHECK pushbutton until Meter 2 flashes, and then repeat Steps 2-3 for
Meter 2.
Set-point value of 70°F
Important:
The letter "E" appears in the center
of the 3-digit display when the
thermistor is shorted or open.
E
7 0