The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com ® GARAGE DOOR OPENER Model 3885C 3/4HP For Residential Use Only Owner’s Manual ■ Please read this manual and the enclosed safety materials carefully! ■ Fasten the manual near the garage door after installation. ■ The door WILL NOT CLOSE unless the Protector System® is connected and properly aligned. ■ Periodic checks of the opener are required to ensure safe operation.
TABLE OF CONTENTS Introduction 2-5 Adjustment Safety symbol and signal word review........................2 Preparing your garage door ........................................3 Tools needed ...............................................................3 Planning .....................................................................4 Carton inventory ..........................................................5 Hardware inventory .....................................................
Preparing your garage door WARNING Before you begin: • Disable locks. • Remove any ropes connected to garage door. • Complete the following test to make sure your garage door is balanced and is not sticking or binding: 1. Lift the door about halfway as shown. Release the door. If balanced, it should stay in place, supported entirely by its springs. 2. Raise and lower the door to see if there is any binding or sticking.
Planning Identify the type and height of your garage door. Survey your garage area to see if any of the conditions below apply to your installation. Additional materials may be required. You may find it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener. SECTIONAL DOOR INSTALLATION FINISHED CEILING Support bracket & fastening hardware is required. See page 12.
Carton Inventory Your garage door opener is packaged in two cartons which contain the motor unit and all parts illustrated below. Accessories will depend on the model purchased. If anything is missing, carefully check the packing material. Parts may be stuck in the foam. Hardware for installation is also listed below.
WARNING CAUTION ASSEMBLY STEP 1 Attach the Rail to the Motor Unit To avoid SERIOUS damage to opener, ONLY use bolts/fasteners mounted in top of motor unit. To avoid installation difficulties, do not run the garage door opener until instructed to do so. • Remove the bolt and lock nut from the top of the motor unit. • Place rail onto the bolt mounted on the motor unit and align the back hole with the hole in the top of the unit. • Fasten rail with the washered bolt and lock nut previously removed.
WARNING ASSEMBLY STEP 3 Attach the Belt Cap Retainer To avoid possible SERIOUS INJURY to fingers from moving garage door opener: • ALWAYS keep hand clear of sprocket while operating opener. • Securely attach sprocket cover BEFORE operating. CAUTION • Position the belt cap retainer over the motor unit sprocket so the two holes in cap align with the two holes in mounting plate. Attach with 8x3/8" hex screws provided. You have now finished assembling your garage door opener.
INSTALLATION STEP 1 Unfinished Ceiling Determine the Header Bracket Location WARNING WARNING 2x4 Header Wall To prevent possible SERIOUS INJURY or DEATH: • Header bracket MUST be RIGIDLY fastened to structural support on header wall or ceiling, otherwise garage door might not reverse when required. DO NOT install header bracket over drywall. • Concrete anchors MUST be used if mounting header bracket or 2x4 into masonry.
INSTALLATION STEP 2 Install the Header Bracket Wall Mounting Holes You can attach the header bracket either to the wall above the garage door, or to the ceiling. Follow the instructions which will work best for your particular requirements. Do not install the header bracket over drywall. If installing into masonry, use concrete anchors (not provided). CEILING MOUNT ONLY The nail hole is for positioning only. You must use lag screws to mount the header bracket.
INSTALLATION STEP 3 Attach the Rail to the Header Bracket • Position the opener on the garage floor below the header bracket. Use packing material as a protective base. NOTE: If the door spring is in the way you’ll need help. Have someone hold the opener securely on a temporary support to allow the rail to clear the spring. • Position the rail bracket against the header bracket. • Align the bracket holes and join with a clevis pin as shown. • Insert a ring fastener to secure.
WARNING CAUTION INSTALLATION STEP 4 Position the Opener To prevent damage to garage door, rest garage door opener rail on 2x4 placed on top section of door. Follow instructions which apply to your door type as illustrated. SECTIONAL DOOR OR ONE-PIECE DOOR WITH TRACK A 2x4 laid flat is convenient for setting an ideal door-to-rail distance. • Remove foam packaging. • Raise the opener onto a stepladder. You will need help at this point if the ladder is not tall enough.
WARNING INSTALLATION STEP 5 Hang the Opener To avoid possible SERIOUS INJURY from a falling garage door opener, fasten it SECURELY to structural supports of the garage. Concrete anchors MUST be used if installing any brackets into masonry. CAUTION Three representative installations are shown. Yours may be different. Hanging brackets should be angled (Figure 1) to provide rigid support.
WARNING WARNING INSTALLATION CAUTION STEP 6 WARNING Install the Control Console Locate control console within sight of door, at a minimum height of 5' (1.5 m) where small children cannot reach, away from moving parts of door and door hardware. If installing into drywall, drill 5/32" holes and use the anchors provided. For pre-wired installations (as in new home construction), it may be mounted to a single gang box (Figure 1).
WARNING CAUTION INSTALLATION STEP 7 Install the Light To prevent possible OVERHEATING of the endpanel or light socket: • DO NOT use short neck or specialty light bulbs. • DO NOT use halogen bulbs. Use ONLY incandescent. To prevent damage to the opener: • DO NOT use bulbs larger than 100W. • ONLY use A19 size bulbs. • Press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is in the fully open position. Do not remove the lens.
WARNING STEP 9 INSTALLATION WARNING Electrical Requirements To prevent possible SERIOUS INJURY or DEATH from electrocution or fire: • Be sure power is not connected to the opener and disconnect power to circuit BEFORE removing cover to establish permanent wiring connection. • Garage door installation and wiring MUST be in compliance with ALL local electrical and building codes. • NEVER use an extension cord, 2-wire adapter or change plug in ANY way to make it fit outlet. Be sure the opener is grounded.
WARNING INSTALLATION STEP 10 Install The Protector System ® Be sure power is not connected to the garage door opener BEFORE installing the safety reversing sensor. To prevent SERIOUS INJURY or DEATH from a closing garage door: • Correctly connect and align the safety reversing sensor. This required safety device MUST NOT be disabled. • Install the safety reversing sensor so beam is NO HIGHER than 6" (15 cm) above garage floor.
INSTALLING THE BRACKETS Be sure power to the opener is disconnected. Install and align the brackets so the sensors will face each other across the garage door, with the beam no higher than 6" (15 cm) above the floor. They may be installed in one of three ways, as follows. Figure 1 DOOR TRACK MOUNT (RIGHT SIDE) Door Track Lip Garage door track installation (preferred): • Slip the curved arms over the rounded edge of each door track, with the curved arms facing the door.
MOUNTING AND WIRING THE SAFETY REVERSING SENSORS • Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension (Figure 5). • Finger tighten the wing nuts. • Run the wires from both sensors to the opener. Use insulated staples to secure wire to wall and ceiling. • Strip 7/16" (11 mm) of insulation from each set of wires.
WARNING CAUTION INSTALLATION STEP 11 Fasten the Door Bracket Fiberglass, aluminum or lightweight steel garage doors will require reinforcement BEFORE installation of door bracket. Contact your door manufacturer for reinforcement kit. Follow instructions which apply to your door type as illustrated below or on the following page. A horizontal reinforcement brace should be long enough to be secured to two or three vertical supports. A vertical reinforcement brace should cover the height of the top panel.
ONE-PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page. They apply to one-piece doors also. • Center the door bracket on the top of the door, in line with the header bracket as shown. Mark either the left and right, or the top and bottom holes. • Metal Doors: Drill 3/16" pilot holes and fasten the bracket with the 1/4"-14x5/8" self-threading screws provided.
INSTALLATION STEP 12 Inner Trolley Connect the Door Arm to the Trolley Follow instructions which apply to your door type as illustrated below and on the following page. Outer Trolley SECTIONAL DOORS ONLY • Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley. Slide the outer trolley back (away from the door) about 2" (5 cm) as shown in Figures 1, 2 and 3.
ALL ONE-PIECE DOORS 1. Assemble the door arm, Figure 4: • Fasten the straight and curved door arm sections together to the longest possible length (with a 2 or 3 hole overlap). • With the door closed, connect the straight door arm section to the door bracket with the 5/16"x1-1/4" clevis pin. • Secure with a ring fastener. 2. Adjustment procedures, Figure 5: • On one-piece doors, before connecting the door arm to the trolley, the travel limits must be adjusted.
WARNING ADJUSTMENT STEP 1 Adjust the Travel Limits Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system. • If one control (force or travel limits) is adjusted, the other control may also need adjustment. • After ANY adjustments are made, the safety reversal system MUST be tested.
WARNING ADJUSTMENT STEP 2 Adjust the Force Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Too much force on garage door will interfere with proper operation of safety reversal system. • NEVER increase force beyond minimum amount required to close garage door. • NEVER use force adjustments to compensate for a binding or sticking garage door.
WARNING ADJUSTMENT STEP 3 Test the Safety Reversal System Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Safety reversal system MUST be tested every month. • If one control (force or travel limits) is adjusted, the other control may also need adjustment. • After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.
WARNING OPERATION IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of SEVERE INJURY or DEATH: 1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS. 2. ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with garage door control push buttons or remote controls. 3. ONLY activate garage door when it can be seen clearly, it is properly adjusted and there are no obstructions to door travel. 4. ALWAYS keep garage door in sight until completely closed.
Using the Wall-Mounted Control Console (PROG) Learn Feature The control console is equipped with a Prog button to assist in learning remote controls to the unit. Press the Prog button once to initiate LEARN mode and the display will show ‘Learn Remote Control - Press Learn Button Again to Confirm’. Press the Prog button a second time and the display will show ‘Learn Mode - Press Remote Control Button to Learn Remote.
To Open the Door Manually WARNING WARNING To prevent possible SERIOUS INJURY or DEATH from a falling garage door: • If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly. • NEVER use emergency release handle unless garage doorway is clear of persons and obstructions. • NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.
THE REMOTE CONTROL BATTERY CARE OF YOUR OPENER WARNING LIMIT AND FORCE ADJUSTMENTS: Weather conditions may FORCE CONTROLS cause some minor changes in door operation requiring some re-adjustments, particularly during the first year of operation. Pages 23 and 24 refer to the LIMIT CONTROLS limit and force adjustments. Only a screwdriver is required. Follow the instructions carefully. Repeat the safety reverse test (Adjustment Step 3, page 25) after any adjustment of limits or force.
HAVING A PROBLEM? 1. My door will not close and the light bulbs blink on my motor unit: The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction. • Verify the safety sensors are properly installed, aligned and free of any obstructions. Refer to Installation Step 10: Install The Protector System®. • Check diagnostic LED for flashes on the motor unit then refer to the Diagnostic Chart on the following page.
Bell Wire Diagnostics Located On Motor Unit Safety Reversing Sensor "Learn" Button LED or Diagnostic LED Diagnostic Chart 1 FLASH Safety reversing sensors wire open (broken or disconnected). OR 2 FLASHES Safety reversing sensors wire shorted or black/white wire reversed. 3 FLASHES Door control or wire shorted. 4 FLASHES Safety reversing sensors slightly misaligned (dim or flashing LED). 5 FLASHES Motor overheated or possible RPM sensor failure. Unplug to reset. 6 FLASHES Motor Circuit Failure.
PROGRAMMING NOTICE: If this Security✚® garage door opener is operated with a non-rolling code transmitter, the technical measure in the receiver of the garage door opener, which provides security against code-theft devices, will be circumvented. The owner of the copyright in the garage door opener does not authorize the purchaser or supplier of the non-rolling code transmitter to circumvent that technical measure.
To Add, Reprogram or Change a Keyless Entry PIN NOTE: Your new Keyless Entry must be programmed to operate your garage door opener. USING THE “LEARN” BUTTON USING THE LCD MOTION DETECTING DOOR CONTROL 1. Press and release the “learn” button on motor unit. The learn indicator light will glow steadily for 30 seconds. NOTE: This method requires two people if the Keyless Entry is already mounted outside the garage. 1. Press the Prog button on the LCD/Motion Detecting Control Console. 2.
REPAIR PARTS Rail Assembly Parts 6 3 1 7 4 2 5 KEY NO. 1 2 3 4 5 6 7 8 8 PART NO. 4A1008 41B5424 41B3869-1 109B33 2777BD 41A5434-11 41B4103 83A11-2 DESCRIPTION Master link kit Belt pulley bracket Complete trolley assembly Trolley clip One-piece T-rail Full belt assembly Tensioner assembly Rail grease Installation Parts 4 2 1 3 KEY PART NO. NO.
Motor Unit Assembly Parts 1 4 2 6 3 6 7 5 18 7 17 15 9 19 8A 8B 16 10 8C 12 13 Brown Wire (Down) Contact LIMIT SWITCH ASSEMBLY DN 11 UP 14 Drive Gear Center Limit Contact KEY NO. PART NO.
ACCESSORIES 1702LMC Outside Quick Release: Required for a garage with NO access door. Enables homeowner to open garage door manually from outside by disengaging trolley. 395LMC Remote Light Control: Enables homeowner to turn on a lamp, television or other appliance from their car with their garage door opener remote or from anywhere in their home with an additional LiftMaster Security✚® remote. 8 Foot (2.4 m) Complete Rail: To allow an 8 foot (2.4 m) door to open fully.
NOTES 37
NOTES 38
NOTES 39
LIFTMASTER SERVICE IS ON CALL HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA AND CANADA Selling prices will be furnished on request or parts will be shipped at prevailing prices and you will be billed accordingly. INSTALLATION AND SERVICE INFORMATION IS AS NEAR AS YOUR TELEPHONE.
The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com ® OUVRE-PORTE DE GARAGE Modèle 3885C 3/4HP Pour résidences seulement Manuel d’instructions ■ Lire attentivement ce manuel ainsi que les consignes de sécurité! ■ Après la pose, accrocher ce manuel près de la porte de garage pour s’y reporter ultérieurement. ■ La porte NE SE FERMERA PAS si le Système Protector® n’est pas branché et réglé correctement.
TABLE DES MATIÈRES Introduction 2-5 Réglages Revue des symboles de sécurité et des mots de signalement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Préparation de votre porte de garage . . . . . . . . . . . . . . . .3 Outils nécessaires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Planification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Inventaire de la boîte d’emballage . . . . . . . . . . . . . . . . . . .
Préparation de votre porte de garage AVERTISSEMENT Avant de commencer : • Désactiver les serrures. • Retirer toute corde raccordée à la porte de garage. • Réaliser le test suivant pour s’assurer que la porte de garage est équilibrée et qu’elle ne force pas : 1. Soulever la porte à moitié, comme illustré, puis la relâcher. Si elle est équilibrée, elle devrait rester en place, entièrement supportée par ses ressorts. 2. Faire monter et descendre la porte pour s’assurer qu’elle ne force pas.
Planification Identifier le type et la hauteur de votre porte de garage. Examiner la région du garage pour noter si l’une des conditions ci-après s’applique à votre installation. Des matériaux supplémentaires peuvent être nécessaires. Il vous sera peut-être utile de vous reporter à cette page et aux illustrations qui l’accompagnent en procédant à la pose de l’ouvre-porte. POSE DE PORTE ARTICULÉE PLAFOND FINI Une cornière et des fixations peuvent être requises. Se reporter à la page 12.
Inventaire de la boîte d’emballage Votre ouvre-porte de garage est emballé dans deux boîtes qui contiennent le moteur et toutes les pièces illustrées ci-après. Les accessoires dépendront du modèle acheté. S’il manque quoi que ce soit, vérifier soigneusement le LOC matériel d’emballage. Les pièces peuvent être coincées dans la mousse. Les ferrures de montage sont également indiquées ci-après.
AVERTISSEMENT ATTENTION MONTAGE - 1re OPÉRATION Fixation du rail au moteur Pour éviter des dommages SÉRIEUX à l’ouvre-porte, utiliser UNIQUEMENT les boulons et les fixations montés sur le dessus du moteur. Pour éviter les difficultés pendant la pose, ne faire fonctionner l'ouvre-porte de garage que lorsque cela est expressément indiqué. • Retirer le boulon et le contre-écrou du dessus du moteur.
AVERTISS AVERTISSEMENT MONTAGE - 3E OPÉRATION Attachement du capuchon de maintien de la courroie Pour éviter d’éventuelles LÉSIONS GRAVES aux doigts par suite du mouvement de l’ouvre-porte : • TOUJOURS garder la main à l’écart du pignon en faisant fonctionner l’ouvre-porte. • Fixer solidement le carter du pignon AVANT de faire fonctionner.
POSE – 1re OPÉRATION Plafond non fini Déterminer l’emplacement du support de linteau MONTAGE DU SUPPORT DE LINTEAU AU PLANFOND EN OPTION AVERTISSEMENT 2x4 Linteau Pour prévenir d’éventuelles BLESSURES GRAVES ou LA MORT : • Le support de linteau DOIT être fixé DE MANIÈRE RIGIDE à la solive sur le linteau ou le plafond, sinon la porte de garage pourrait ne pas remonter au besoin. NE PAS poser le support de linteau sur des plaques de placoplâtre.
POSE – 2e OPÉRATION Pose du support de linteau Trous de fixation au mur Le support de linteau peut être fixé soit sur le mur, au-dessus de la porte, soit au plafond. Suivre les instructions qui répondent le mieux aux besoins particuliers. Ne pas poser le support de linteau sur des panneaux de placoplâtre. Utiliser des ancrages de béton (non fournis) pour la pose dans la maçonnerie. CEILING MOUNT ONLY Le trou du clou n'est prévu que pour le positionnement seulement.
POSE - 3e OPÉRATION Fixation du rail sur le support de linteau • Positionner l’ouvre-porte de garage sur le plancher, juste sous le support de linteau. Utiliser une des boîtes d’emballage pour le protéger. REMARQUE : Si le ressort de la porte gêne, il faudra demander de l’aide. Demander à une personne de bien retenir l’ouvre-porte sur un support temporaire de façon que le rail ne touche pas le ressort. • Positionner le support du rail contre le support de linteau.
AVERTISSEMENT ATTENTION POSE - 4e OPÉRATION Positionnement de l’ouvre-porte Pour prévenir les dommages à la porte de garage, faire reposer le rail de l’ouvre-porte de garage sur un 2 x 4 placé sur la section supérieure de la porte. Suivre les instructions qui se rapportent à la porte de garage particulière, en se rapportant aux illustrations. PORTE ARTICULÉE OU PORTE RIGIDE AVEC GUIDES Un 2 x 4 posé à plat convient très bien pour obtenir l’espace qu’il faut entre la porte et le rail.
AVERTISSEMENT POSE - 5e OPÉRATION Accrochage de l’ouvre-porte Pour éviter d’éventuelles BLESSURES GRAVES par suite de la chute d’un ouvre-porte de garage, fixer l’ouvre-porte SOLIDEMENT aux solives du garage. On DOIT utiliser des ancrages de béton si les supports sont posés dans la maçonnerie. AVERTISSEMENT AVERTIS ATTENTION AVERTIS Les illustrations représentent trois poses types. La pose peut toutefois être différente.
AVERTISSEMENT AVERTISSEMENT POSE - 6e OPÉRATION ATTENTION AVERTISSEMENT Pose de la commande de porte Poser la commande murale dans un endroit où on pourra la voir de la porte, à au moins 5 pieds (1,5 m) du sol, là où les enfants ne pourront pas l'atteindre et loin de toutes les pièces mobiles et fixations de la porte. Si les murs sont des murs secs, percer des trous de 5/32 de pouce et utiliser les chevilles fournies.
AVERTISSEMENT ATTENTION POSE - 7e OPÉRATION Pose des l’ampoule Pour éviter toute SURCHAUFFE éventuelle du panneau d’éclairage, • NE PAS utiliser d’ampoules à col court ou de forme spéciale. • NE PAS utiliser d’ampoules halogène. Utiliser UNIQUEMENT des ampoules incandescentes. Pour empêcher des dommages à l’ouvre-boîte : • NE PAS utiliser d’ampoule plus grandes que 100W. • SEULEMENT utiliser A19 ampoules de taille. • Appuyer sur les pattes de dégagement des deux côtés du diffuseur.
AVERTISSEMENT AVERTISSEMENT POSE - 9e OPÉRATION AVERTISSEMENT Exigences électriques Pour prévenir d’éventuelles BLESSURES GRAVES ou LA MORT par suite d’électrocution ou d’un incendie : • S’assurer que l’ouvre-porte est hors tension et couper le courant au circuit AVANT de retirer le couvercle pour procéder à un branchement permanent. • La pose et le câblage de la porte de garage DOIVENT être conformes à TOUS les codes électriques et de construction locaux.
AVERTISSEMENT POSE - 10e OPÉRATION Pose du Système Protector ® S’assurer que l’ouvre-porte de garage est hors tension AVANT de poser le détecteur inverseur de sécurité. Pour prévenir des BLESSURES GRAVES ou LA MORT par suite d’une porte de garage qui se ferme : • Raccorder et aligner correctement le détecteur inverseur de sécurité. Ce dispositif de sécurité requis NE DOIT PAS être désactivé.
POSE DES SUPPORTS S’assurer que l’ouvre-porte est hors tension. Poser et aligner les supports de manière à ce que les détecteurs se fassent face l’un l’autre de part et d’autre de la porte du garage, le faisceau n’étant pas à une hauteur de plus de 6 po (15 cm) au-dessus du sol. Ils peuvent être posés de trois façons, comme suit.
MONTAGE ET CÂBLAGE DES DÉTECTEURS INVERSEURS DE SECURITÉ • Faire glisser un boulon à tête bombée et collet carré de 1/4 po-20 x 1/2 po dans la fente de chaque détecteur. Utiliser des écrous à oreilles pour fixer les détecteurs aux supports, avec les diffuseurs dirigés l’un vers l’autre de part et d’autre de la porte. S’assurer que le diffuseur n’est pas obstrué par une rallonge de support (Figure 5). • Serrer les écrous à oreilles à la main. • Acheminer les fils des deux détecteurs à l’ouvre-porte.
AVERTISSEMENT ATTENTION POSE - 11e OPÉRATION Fixation du support de la porte Les portes de garage en fibre de verre, en aluminium ou en acier léger ont BESOIN d’être renforcées AVANT la fixation du support de porte. Il est conseillé de s’adresser au fabricant de la porte pour obtenir un nécessaire de renforts. Suivre les instructions qui correspondent au type de porte, comme il est illustré ci-dessous ou à la page suivante.
PORTES RIGIDES Prière de lire et de suivre les avertissements et les instructions de renforcements à la page précédente. Ils s’appliquent également aux portes rigides. • Centrer le support de porte sur le dessus de la porte, en l’alignant avec le support de linteau, comme il est illustré. Repérer soit les trous de gauche et de droite, soit les trous du haut et du bas.
POSE - 12e OPÉRATION Chariot intérieur Fixation de la biellette au chariot Chariot extérieur Suivre uniquement les instructions se reportant à votre type de porte, comme illustré ci-dessous et à la page suivante. PORTE ARTICULÉE SEULEMENT • S’assurer que la porte du garage est complètement fermée. Tirer la poignée de déclenchement d’urgence pour détacher le chariot extérieur du chariot intérieur.
POUR TOUTES LES PORTES RIGIDES 1. Assemblage des biellettes, Figure 4 : • Assembler les biellettes droite et courbée à leur plus grande longueur (2 ou 3 trous se chevauchant). • La porte étant fermée, raccorder la biellette droite au support de la porte à l’aide d’un axe de chape de 5/16 po x 1-1/4 po. • Faire tenir l’axe de chape avec un anneau d’arrêt. 2. Méthodes de réglage, Figure 5 : • Dans le cas d’une porte rigide, la course doit être réglée avant de raccorder la biellette au chariot.
AVERTISSEMENT RÉGLAGES - 1re OPÉRATION Réglage des courses d’ouverture et de fermeture Sans un système d’inversion de sécurité bien installé, des personnes (plus particulièrement les petits enfants) pourraient être GRIÈVEMENT BLESSÉES ou TUÉES par une porte de garage qui se referme. • Un réglage erroné des courses de la porte de garage gênera un fonctionnement approprié du système d’inversion de sécurité.
AVERTISSEMENT RÉGLAGES - 2e OPÉRATION Réglage de la force Sans un système d’inversion de sécurité bien installé, des personnes (plus particulièrement les petits enfants) pourraient être GRIÈVEMENT BLESSÉES ou TUÉES par une porte de garage qui se referme. • Une trop grande force sur la porte de garage gênera un fonctionnement approprié du système d’inversion de sécurité. • Ne JAMAIS augmenter la force au-delà du niveau nécessaire à la fermeture de la porte.
AVERTISSEMENT RÉGLAGES - 3e OPÉRATION Essai du système d’inversion de sécurité Sans un système d’inversion de sécurité bien installé, des personnes (plus particulièrement les petits enfants) pourraient être GRIÈVEMENT BLESSÉES ou TUÉES par une porte de garage qui se referme. • On DOIT procéder à une vérification mensuelle du système d’inversion de sécurité. • Après avoir réglé une commande (force ou course), il peut être nécessaire de régler l’autre commande.
FONCTIONNEMENT AVERTISSEMENT IMPORTANTES CONSIGNES DE SÉCURITÉ AVERTISSEMENT Pour réduire le risque de BLESSURES GRAVES ou de MORT : 1. LIRE ET SUIVRE TOUS LES AVERTISSEMENTS ET INSTRUCTIONS. 2. TOUJOURS garder les télécommandes hors de la portée des enfants. Ne JAMAIS laisser les enfants faire fonctionner les télécommandes ou les boutons-poussoirs de la commande de porte ou jouer avec ceux-ci. 3.
Utilisation de la commande de porte à montage mural Pour désactiver cette fonctionnalité, appuyer sur le bouton ON/OFF (marche-arrêt) d'éclairage automatique sur le côté gauche de la console de commande. Il est recommandé de désactiver le détecteur de mouvement en cas d'usage de l'éclairage de l'ouvre-porte comme éclairage de travail. Sinon, l'éclairage s'éteindra automatiquement si les travaux s'effectuent au-delà de la portée du détecteur.
Ouverture manuelle de la porte AVERTISSEMENT Pour prévenir d’éventuelles BLESSURES GRAVES ou LA MORT par suite de la chute d’une porte de garage : • Si possible, utiliser la poignée de déclenchement d’urgence pour dégager le chariot UNIQUEMENT lorsque la porte de garage est FERMÉE. Des ressorts faibles ou brisés ou une porte déséquilibrée peuvent causer la chute rapide ou imprévue d’une porte ouverte.
LA PILE DE LA TÉLÉCOMMANDE ENTRETIEN DE L’OUVRE-PORTE DE GARAGE AVERTISSEMENT RÉGLAGES DE COURSE ET DE FORCE : Les conditions climatiques COMMANDES DE FORCE risquent de causer de petites modifications dans le fonctionnement de la porte qui devra alors être réglée, en KG KG particulier après la première année d’utilisation. COMMANDES DE COURSE Se reporter aux pages 23 et 24 pour les réglages des courses d’ouverture et de fermeture et de la force. Seul un tournevis est requis.
DÉFAUTS DE FONCTIONNEMENT 1. Ma porte ne se ferme pas et les ampoules de l’éclairage du moteur clignotent : Le détecteur inverseur de sécurité doit être raccordé et aligné correctement avant que l’ouvre-porte de garage n’entame la procédure de fermeture. • Vérifier que les détecteurs inverseurs de sécurité sont bien installés et dépourvus d’obstruction. Se reporter à la 10e étape de pose : Pose du Système Protector®.
Fil de sonnerie Diagnostic situé sur le moteur Voyant LED ou LED diagnostic Détecteur inverseur de sécurité Bouton « Learn » Fiche Diagnostique 1 ÉCLAIR Cassure du fil des détecteurs inverseur de sécurité (coupé ou déconnecté). OU 2 ÉCLAIRS Court-circuit du fil des détecteurs inverseur de sécurité ou inversion des fils noir/blanc. 3 ÉCLAIRS Court-circuit de la commande de porte ou du fil. 4 ÉCLAIRS Léger mésalignement des détecteurs inverseurde sécurité (témoin LED faible ou clignotant).
PROGRAMMATION REMARQUE : Si cet ouvre-porte de garage Security✚® est utilisé avec une télécommande émettrice à code fixe, le dispositif technique que contient le récepteur de l’ouvre-porte et qui procure une protection contre les vols de code, se trouvera contourné. Le détenteur des droits d’auteur de cet ouvre-porte de garage n’autorise pas l’acheteur ni le fournisseur de la télécommande émettrice à code fixe à contourner ce dispositif technique.
Pour ajouter, reprogrammer ou modifier un NIP d’entrée sans clé REMARQUE : Votre nouvelle entrée sans clé doit être programmée de manière à faire fonctionner votre ouvre-porte de garage. UTILISATION DU BOUTON « LEARN » UTILISATION DE LA CONSOLE DE COMMANDE DE ACL REMARQUE : Cette méthode nécessite deux personnes si le pavé pour l’entrée sans clé est déjà monté à l’extérieur du garage. 1. Enfoncer et tenir le bouton « learn » sur le moteur.
PIÈCES DE RECHANGE Pièces d’assemblage du rail 6 3 1 7 4 2 5 N° DE RÉF. PIÈCE 1 2 3 4 5 6 7 8 8 Pièces pour la pose 4 4A1008 41A5424 41B3869-1 109B33 2777BD 41A5434-11 41B4103 83A11-2 DÉSIGNATION Maillon de raccord Support de poulie de courroie Chariot complet Pince de chariot Rail rigide Ensemble courroie complet Ensemble tendeur Graisse à rail 2 1 3 N° DE RÉF.
Pièces d’assemblage du moteur 1 4 2 6 3 6 7 5 18 7 17 15 9 8A 19 8B 16 10 8C 13 12 Contact (fermeture) Fil brun 11 INTERRUPTEUR DE FIN DE COURSE DN UP 14 Pignon menant Contact de fin de course central RÉF. N° DE PIÈCE 1 41A4371 2 41A4885-5 3 41A2817 4 5 41B4245-1 41D5484 6 7 8A 8B 8C 9 10 4A1344 108D79 30B530 30B529 41A5637 41A3150 41D5563-1 DÉSIGNATION RÉF.
ACCESSOIRES 1702LMC Détachement rapide d'extérieur : Nécessaire pour un garage SANS porte d'accès. Permet au propriétaire d'ouvrir la porte de garage manuellement à partir de l'extérieur en déconnectant le chariot. 2778BD Rail complet de 8 pieds (2,4 m) : Pour permettre à une porte de 8 pieds (2,4 m) de s'ouvrir complètement.
REMARQUES 37
REMARQUES 38
REMARQUES 39
SERVICE LIFTMASTER À VOTRE DISPOSITION COMMENT COMMANDER DES PIÈCES DE RECHANGE NOTRE IMPORTANT ORGANISATION DE SERVICE APRÈS-VENTE COUVRE TOUTE LES ÉTATS-UNIS ET CANADA. Les prix de vente seront fournis sur demande, ou bien les pièces seront expédiées au prix en vigueur et vous seront facturées en conséquence.