User's Manual

26
SET OPEN
SET CLOSE
MOVE
GATE
OFF
5
10
60
180
MIN
MAX
(SECONDS)
OFF
ON
OPEN
CLOSE
STOP
INPUT POWER
BATT CHARGING
TIMER
GATE MOVING
BATT LOW
ACC PWR OVLD
DIAGNOSTIC
CODES
BIPART
DELAY
LEARN
TEST
BUTTONS
TIMER
TO CLOSE
REVERSAL
FORCE
STATUS:
OPEN
CLOSE
STOP
COMMON
“FIRE
DEPT.
OPEN
EXIT
SHADOW
INTERRUPT
COMM
LINK
B A
- +
- +
EYES
EDGE
LOCK
N.O.
COM
N.C.
+ -
+ -
ACCESSORY
POWER
ON SW.
EXP.
BOARD
RESETENCODER
ID IN ALARM
SECURE / MANUAL
+ -
MOTOR
+ -
DC POWER
+ -
BATT
BATT FUSE
30A 32V
1
6
3
4
XMITTER
NETWORK
PRESS &
RELEASE
TO BEGIN
SETUP
LIMIT
CLOSE
OPEN
DC POWER FUSE
30A
32V
CLASS 2 SUPPLY
24 VOLTS
Open
Close
Stop
Com
Com
Com
Com
Com
Com (-)
Fire Dept
Exit
Shadow
Interrupt
Comm Link Power +24 Vdc
Comm Link Data A
Comm Link Data B
Close (+)
Close (-)
Lock N.C. (Solenoid)
Com
Lock N.O. (Maglock)
Com (-)
AccPower +24 Vdc
Com (-)
AccPower +24 Vdc
3 Button
Station
Fire Dept.
Exit Loop
Shadow Loop
Interrupt Loop
Comm Link
Open Direction
Safety
Close Direction
Safety
Mag and
Solenoid Lock
A
B
C
D
E
F
G
H
I
J
K
L
M
N
CONTROL BOARD OVERVIEW
ADDITIONAL FEATURES
CONTROL BOARD OVERVIEW
SET OPEN Button The SET OPEN button sets the OPEN limit. See Adjust Limits section.
SET CLOSE Button The SET CLOSE button sets the CLOSE limit. See Adjust Limits section.
MOVE GATE Button The MOVE GATE buttons will either open or close the gate when the operator is in Limit setting mode. See Adjust Limits section.
BIPART DELAY Switch
The Bipart delay switch is used only for dual gates. See Bipart Delay section.
LEARN Button
The LEARN button is for programming remote controls and the network.
TIMER-TO-CLOSE dial
The TIMER-TO-CLOSE (TTC) dial can be set to automatically close the gate after a specified time period. The TTC is factory set to OFF. If the
TTC is set to the OFF position, then the gate will remain open until the operator receives another command from a control. Rotate the
TIMER-TO-CLOSE dial to the desired setting. The range is 0 to 180 seconds, 0 seconds is OFF.
NOTE: Any radio command, single button control, or CLOSE command on the control board prior to the TTC expiring will close the gate.
The TTC is reset by any signals from the open controls, loops, close edges, and close safety sensors (IR’s).
REVERSAL FORCE dial
The REVERSAL FORCE dial adjusts the force. See Force Adjustment section.
TEST BUTTONS
The TEST BUTTONS will operate the gate (OPEN, STOP and CLOSE).
STATUS LEDs
The STATUS LEDs are diagnostic codes for the operator. See Status LED Chart in the Troubleshooting section.
Switched ON with gate motion. Always ON with
expansion board connected. Switches Off to save
battery power if expansion board disconnected.
Always ON
Acc. Power