Brochure


www.centuryelectricmotors.ca
NEMA C-Face 3-Phase Pump Motors

• Ball Bearings NEMA “56C” Mount Internal Junction Box
• Continuous Duty 40°C Ambient • Keyed and Stainless Steel Threaded Shafts
• Open Dripproof 60 Hz
NEMA C Face mounting bracket, and end frames are die-cast corrosion resistant aluminum, accurately machined for maximum
concentricity, and minimum runout. Stator assemblies are press fitted into rolled steel main frames. Double shielded ball bearings, selected for
quiet operation, are lubricated for life with greases specifically chosen for moisture and heat resistant qualities.
1/2” x 14 thread tapped opening is provided for conduit fitting. No external junction box required connections made under motor canopy. Motors
are supplied with horizontal canopy but are easily converted for vertical operation with the use of optional vertical canopy (#621335-002).
Max. Service Stock Approx.
HP RPM Volts Amps Factor THP Frame Number Shaft Protector “AG” Notes
1/2 3450 208-230/460 2.7/1.35 1.6 0.8 56J T3052 Thrd None 8-5/8
3/4 3450 208-230/460 3.4/1.7 1.5 1.125 56C K3072 Key None 9-1/8
3/4 3450 208-230/460 3.4/1.7 1.5 1.125 56J T3072 Thrd None 9-1/8
1 3450 208-230/460 4.0/2.0 1.4 1.4 56C K3102 Key None 9-11/16
1 3450 208-230/460 4.0/2.0 1.4 1.4 56J T3102 Thrd None 9-11/16
1-1/2 3450 208-230/460 6.8/3.4 1.3 1.95 56C K3152 Key None 11-5/16
1-1/2 3450 208-230/460 6.8/3.4 1.3 1.95 56J T3152 Thrd None 11-5/16
2 3450 208-230/460 8.6/4.3 1.2 2.4 56C K3202 Key None 11-5/16
2 3450 208-230/460 8.6/4.3 1.2 2.4 56J T3202 Thrd None 11-5/16
THREE PHASE SQUARE FLANGE PUMP MOTORS

AllCopperWindings•OpenDripproof•303StainlessSteelThreadedShaft•SealedBallBearings•50°CAmbient•60Hz
Featur
dBall
Bearings
Amps Service Stock Overload Approx.
HP RPM Volts Hi - Lo Factor THP Frame Number Protector “AG”
1/2 3450 208-230/460 3.0/1.5 1.9 .95 48Y Q3052 None 9-7/8
3/4 3450 208-230/460 3.6/1.8 1.65 1.24 48Y Q3072 None 10-3/8
1 3450 208-230/460 4.7/2.35 1.65 1.65 48Y Q3102 None 10-7/8
1-1/2 3450 208-230/460 6.8/3.4 1.47 2.21 48Y Q3152 None 11-7/8
2 3450 208-230/460 8.5/4.25 1.3 2.6 48Y Q3202 None 12-5/8
3 3450 200-230/460 9.7/4.9 1.15 3.45 56Y Q3302V1 None 12
T3052
Important:
1. Total output (HP x service factor) of replacement motor
must equal or exceed motor being replaced.
2. The pool motors on this page are NOT equipped with a
Safety Vacuum Release System (SVRS). SVRS helps
prevent drowning due to body entrapment on underwater
drains. In some pool configurations, if a person’s body
covers the drain, the person can be trapped by suction.
The SVRS turns off the pump if this occurs.
Depending on your pool configuration,
a SVRS may be required to meet local, state, and federal
requirements.
Q3052