Specifications

R-82
Manager Operation
3. Manager operation
This section describes manager operations (such as machine initialization, IPL, manager
functions etc.) of QT-6000.
3-1. Machine initialization
There are three different types of initialization such as INIT, FC, and INIT2.
INIT; Machine initialization, all program and total data are reset.
FC; Flag clear, all program and total data are remained, only the current transaction data
are reset.
INIT2; Machine initialization 2, all program data are remained, only total data are reset.
The procedures of machine initialization are described in the chapter 1 of the programming
manual. The required passwords are listed below.
3-1-2. Flag clear
Flag clear process is as follows:
3-1-1. INIT
Initialization process is as follows:
Start
End
Hardware reset
All RAM reset
Inline ID definition
File creation 1
File creation 2
Initialization result
to E-journal
Revise terminal
connection table
Input password
(see above)
Initialization operation
Input date/time, ID etc.
Receiving program
f
rom other terminal or
CF card
Start
Hardware reset
Initialize work area/
buffers/flags
Initialization result
to E-journal
End
Menu selection
FC/Init2
Init 2
Operation Password Digit meaning
00020000 for the U.S.
00010000 for other area (default descriptors are initialized in English)
Init
00040000 for other area (default descriptors are initialized in German)
00050000 for other area (default descriptors are initialized in French)
00060000 for other area (default descriptors are initialized in Spanish)
00080000 Arabic (default descriptors are initialized in English)
Flag clear No need
Init2 8888888888
* See the “INIT code” section to notice the detail information of the last four digits.