User manual
9
EN
“UEX-PLUS” +030220621 - rel. 1.1 - 30.05.2008
installeruserservice
turn the red oval-shaped plate with the CAREL logo until covering 4.
the fastening holes.
Models UE025 to UE130
1
2
Fig. 1.l
slip the cover/covers onto the frame (keeping it/them slightly raised
1.
and tilted), until it rests on the rear edges;
tighten the screws on the top of the humidi er using a screwdriver.
2.
Important
Important: in models UE025 to UE130 open the electrical
compartment on the humidi er using the lock with slot.
Fig. 1.m
1.8 Components and accessories
Once having opened the packaging and removed the front cover of the
humidi er, make sure the following are included:
kit of screws with plugs for
wall-mounting;
kit code
98C565P009 of
connectors for the electronic
board
models UE025 to UE130 only:
angular plastic hose (drain
water connection).
models UE025 to UE130 only:
code FWHDCV0000 non-
return valve with connection
pipe