User manual

51
EN
“UEX-PLUS” +030220621 - rel. 1.1 - 30.05.2008
installeruserservice
47 R/W warnings for pre-exhaustion and complete exhaustion: 1 = enabled, 0 = disabled
48 R/W cylinders in parallel or series: 0 = parallel, 1 = series
49 R/W cylinder 1: reset of the hour counter
50 R/W cylinder 2: reset of the hour counter
51 R/W alarms reset
52 R/W cylinder 1: manual drain: 1 = on, 0 = o
53 R/W cylinder 2: manual drain: 1 = on, 0 = o
54 R/W cylinder 1: cleaning cycle: 1 = on, 0 = o
55 R/W cylinder 2: cleaning cycle: 1 = on, 0 = o
“I” read (R)/
write (W)
integer variables (Modbus®: REGISTERS)
CAREL Modbus®
1 129 R high part sw version
2 130 R low part sw version
3 131 R day sw version
4 132 R month sw version
5 133 R year sw version
6 134 R sw release type
7 135 R sw release number
8 136 R humidi er status
0 = on duty; 1 = alarm(s) present; 2 = disabled via network; 3 = disabled by timer; 4 = disabled by remote on/o ; 5
= disabled by keyboard; 6 = manual control; 7 = no demand
9 137 R conductivity reading
10 138 R/W manual force conductivity value
11 139 R cylinder 1: working phase
0 = not active; 1 = softstart; 2 = start; 3 = production at steady state; 4 = reduced production
5 = production delayed stop; 6 = full  ush
12 140 R cylinder 1: status
0 = no production; 1 = start of evaporation cycle; 2 = water  ll; 3 = steam production in progress;
4 = water drain (decision to open the contactor; drain pump still stopped); 5 = water drain (drain pump running); 6 =
water drain (drain pump stopped; contactor closing, if open); 7 = humidi er blocked
8 = long-term-inactivity full drain; 9 =  ushing of the hydraulic circuit; 10 = full drain by manual or network request;
11 = automatic management of lack of supply water; 12 = total periodic drain
13 141 R cylinder 2: working phase
0 = not active; 1 = softstart; 2 = start; 3 = production at steady state; 4 = reduced production; 5 = production delayed
stop; 6 = full  ush
14 142 R cilindro 2: status
0 = no production; 1 = start of evaporation cycle; 2 = water  ll; 3 = steam production in progress;
4 = water drain (decision to open the contactor; drain pump still stopped); 5 = water drain (drain pump running); 6 =
water drain (drain pump stopped; contactor closing, if open); 7 = humidi er blocked
8 = long-term-inactivity full drain; 9 =  ushing of the hydraulic circuit; 10 = full drain by manual or network request;
11 = automatic management of lack of supply water; 12 = total periodic drain
15 143 R/W regulation type:
0 = on/o ; 1 = slave 0-100%; 2 = slave 0-100% + limit probe; 3 = %rh control with external probe without limit probe
4 = %rh control with external probe + limit probe; 5 = temperature control
16 144 R/W room probe/ext. regulator: type of signal
0 = 0-1 v; 1 = 0-10 v; 2 = 2-10 v; 3 = 0-20 ma; 4 = 4-20 ma; 5 = ntc carel standard
17 145 R/W limit probe: type of signal
0 = 0-1 V; 1 = 0-10 V: 2 = 2-10 V; 3 = 0-20 mA; 4 = 4-20 mA; 5 = NTC CAREL standard
18 146 R/W maintenance time-out
19 147 R/W periodical  ush: period
20 148 R/W inactivity drain: time-out
21 149 R/W conductivity warning: threshold
22 150 R/W conductivity alarm: threshold
23 151 R/W tuning of dilution frequency: parameter b8
24 152 R/W tuning of dilution duration: parameter b9
25 153 R system timer: hour
26 154 R system timer: minute