Cooker Use and Installation Instructions
TECHNICAL DATA
DIMENSIONS
Height 1460mm
Width 538mm
Depth 590mm Excluding Handles
Height to Hotplate 900mm
GENERAL
Gas connection Rp
1
/
2
(
1
/
2
”BSP female)
Pressure test point Grill injector
Gas rate adjustment None
Aeration adjustment None
Electrical connection Flexible cord fitted with a 3 pin 13 amp plug
230/240V a.c. 50Hz. 3A fuse.
25
INSTALLATION INSTRUCTIONS
HEAT
INPUT
NATURAL GAS
MODELS
LPG MODELS
BURNER
INJECTOR
4.8 kWGRILL 170
2.7 kWOVEN 120
3.0 kWHOTPLATE
Front left and rear right
128
1.9 kWHOTPLATE
Front right and rear left
102
HEAT
INPUT
INJECTOR
3.7 kW (270g/h)
95
2.4 kW (175g/h) 75
2.8 kW (205g/h) 82
1.8 kW (130g/h) 65