User Command Specifications 9. Details of command PMM
1
PMM
PMM
PMM=<Power management setting parameters:ID>
Power management setting parameters
-1
A "busy" response is given while the zoom or focus lens is being driven.
-2
Menu
[System settings] - [Power management modes]
[System settings] - [Power management modes]
-2
-3
The projector behaves as follows with the power management setting and in the remote mode.
In the remote mode, the power management setting is ignored.
This setting takes effect only when the local mode is established.
-4
Setting
> PMM=STANDBY This sets the power management to "standby."
< i:OK
Reference
>
GET PMM or ?PMM This retrieves the Power management mode.
< g:PMM=EXIT
Acquisition of parameters which can be set
> RANGE PMM
< r:PMM=I, OFF, STANDBY, EXIT
* Commands are indicated by ">", and responses are indicated by "<".
Supported Command State
s
OFF ON PM
× ×
× ×
* If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
01.01** 01.01**
SX60
Even in the remote mode, the projector operates as per the power management
setting.
However, when it starts operating, it is automatically transferred to the "local
mode."
It can be executed when the projector is in both the remote mode and power-on status at the
same time.
X600
○○○
01.00** 01.01**
Setting
Power managemen
t
Reference
Paramete
r
Meaning
OFF
Mode
Control
STANDBY
OFF
Format
Commands
Description
Response
Function
Parameter
X600
Pro
j
ector behavio
r
SX60
The current power management mode can be acquired using the applicable GET command.
Model
Model
SX50 SX6
SX50
SX6
X600
EXIT
This command is the same as the menu functions in the table below.
SX60
ID
SX50
SX6
Exit mode
"i:OK" is returned if the parameter was set properly.
Standby mode
This sets Power management mode.
Model Power
Input
D-RGB A-RGB1 A-RGB2 Comp Video S-Video D-Video
Mode
Remote Local
Remarks
SCART None
SX50
○○○○○○ ––○○ ×
SX6
○○○ ○○ ×○○○○
SX60
X600
Command
s
supported
The parameters which can be set at any given point in time can be obtained using the
RANGE command.
For details, refer to the RANGE command.
For all other responses, refer to "Error List."
(Refer to the ZCONTDRV command and FCONTDRV command.)
With the SX6, SX60 or X600, power management cannot be set to OFF if ON has been
selected as the direct power-on setting (DPON=ON). ("e:1005 DIRECT_POWER_ON" is
Example
For details, refer to the GET command.
"OFF," "STANDBY" or "EXIT" can be set for the power
management.
PAGE 53