Realis Command Codes

Commands
NOSIG Mode Control Setting
Reference
Function Display screen setting when no signal
Parameter
ID
Parameter
Meaning
BLACK
Black screen
BLUE Blue screen
LOGO User screen
The RANGE command can be used to obtain the parameter range that can be set at that time.
Response
An 'i:OK' is returned after setting is successful.
Description
This sets the display screen when no image signals are input.
(1)
This command is identical to the No signal screen function under the User screen settings in the Display
settings menu.
(2)
Before a user screen (LOGO) is designated, the user image needs to be registered beforehand. (Otherwise, a
“e:1002 NO_LOGO_CAPTURED” is returned.)
(3)
The GET command can be used to obtain the current display screen at no signal.
Example
Setting
> NOSIG=BLUE This sets the “Blue” screen when no signals are input.
< i:Ok
Reference
> GET NOSIG or ?NOSIG
This retrieves the screen when no signals are input.
<
g:NOSIG=LOGO
Obtain settable parameters
> RANGE NOSIG
< r:NOSIG=I,BLACK,BLUE,LOGO
Commands are indicated by “>”, and responses are indicated by “<”
Supported Command States
Power supply
Input
Mode
OFF ON PM
D-RGB A-RGB1 A-RGB2 Comp Video S-Video None Remote Local
× ×
○○○○○○ ○○
×
If a state is not supported, “INVALID_MODE” or “NOT_POWER_SUPPLIED” is returned with the Err response.
When the power supply state is in the process of switching, an “i:BUSY” reply may be sent.