User Manual

Operator Manual
Page 86
7. MAINTENANCE
7.1 Preventive maintenance
Daily:
- Carriage: Check the condition of the jaws, remove any trace of glue.
- Glue tank: Check the glue level before switching on the machine.
- Cover clamp: Check the condition of the clamps and the black non-stick plate: remove
any trace of glue.
- Output unit: Check that the baffle plates and guides are clean. Remove any trace of glue.
- External waste collector : Shake the filter (cloth bag).
Weekly:
- General cleaning of the machine.
- Milling: Make sure there is no waste paper in the milling unit and the pipes.
- Glue tank: Check whether the glue is oxidising (turning brown in the case of National
Coolbind 1300), and replace if necessary.
- Waste paper bin: See whether the bag is full
(see chapter "7.2 Replacing the dust bag", page 87).
- Clean the grid of the glue fumes extractor.
Monthly:
- Cover loading: Check the condition of the suction cups.
Consumables*:
Cover separator*:
Aluminium container*: 9199883
Dust bag*: See next page.
* Consumables not covered by service contract.
Glue type CP Bourg Ref
PLANATOL HM
9925 9195046 20 Kg
RELIMELT F
1 5005666 25 Kg
COOLBIND
3730 9195035 20 Kg
Flexible
9403785
Rigid