8) Push the thermal switch t in the direction of the
arrow, and remove it.
Figure 4-708
9) Remove the screw y, and remove the metal
plate u.
Figure 4-709
10) Remove the screw i, and remove the ther-
mistor o.
Figure 4-710
6
7
9
8
5
11) Remove the E-ring !0 at the front, and remove
the bush !1 and the bearing !2; then, pull out the
upper roller.
Figure 4-711
12) Remove the three E-rings !3 at the rear, and
pull out the gear !4 and the bush !5.
Figure 4-712
4. Points to Note after Replacing the
Upper Fixing Unit
If you have replaced the upper fixing unit, you
must enter the temperature adjustment in
service mode No. 304. (See the Service
Handbook.)
Caution:
Do not touch the surface of the heater.