11-42
CHAPTER 11
TROUBLESHOOTING
COPYRIGHT © 1997 CANON INC. CANON NP6330 REV.0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
3) Start [4], and select No. 403 using the keypad.
The indicator indicates ‘403’.
4) Press the OK key.
The indicator indicates ‘NIP’.
Paper will be picked up from the multifeeder and delivered, enabling
measurements as in Figure 11-251.
Reference:
Delivery stops after discharging the paper halfway; it will automatically resume
about 10 sec to fully discharge the paper.
5) Measure the nip.
3 Position of the Fixing Assembly Paper Guide
The paper guide is positioned by the paper guide mount, and you need not adjust its
position when installing the paper guide.
Do not loosen the screw on the paper guide plate; otherwise, you will have to adjust
the position of the paper guide. If you should have loosened it for some reason, be
sure to put the fixing assembly base back to its original position.
4 Position of the Cleaning Belt Solenoid
Install the cleaning belt solenoid so that the solenoid arm w butts against a when
the plunger q of the solenoid is pushed by a finger.
Figure 11-252
Note:
w
q
a