B. Operation of Fixing Assembly Temperature Control System
Figure 6-102
Note:
When the preheat mode starts in response to a press on the STANDBY key, the fixing tem-
perature is controlled to 155°C.
Power switch ON
WARM-UP
50˚C 110˚C COPY START key ON
COPY START key indicator
Fixing roller heater (H1)
Exhaust fan (FM2)
195˚C
180˚C
155˚C
110˚C
50˚C
0˚C
Main motor (M1)
Scanner cooling fan (FM1)
WARM-UP
ROTATION
STAND-BY
SCANNER
FORWARD
SCANNER
REVERSE
Blinks green Glows green Glows red
SCANNER
FORWARD
SCANNER
REVERSE
LAST
ROTATION
Glows green