8.3.9. “02” [CR]
Status: RS232C Command is unacceptable
When a computer receives this response, try to execute Status Read Command
again.
8.3.10. “24” [24]
Status: Processing cooling down by power save
When Power Management function is ON in setting menu and there is no signal for
5 minutes, it moves on to Power Save/Cooling Down after tuning off the lamps.
(During this process, Green LED is OFF)
The control command is invalid.
After this cooling down continues for about 90 seconds, it moves on to power save.
(Green LED flashes)
Status: No signal Cooling down by power save Power save
Response: “00” 24 04
After 5 minutes with no signal After about 90 seconds
8.3.11. “04” [CR]
Status: Power Save
When the Power Management function is ON in setting menu, and there is no
signal for 5 minutes, it moves on to power save status after power save and cooling
down.
Control commands as below are available in this status.
*Power ON Command: “C00” [CR] --------- Move on the status of power on
*Power OFF Command: “C01” [CR] -------- Move on the status of standby
Moving on to the status of Power ON is the same action as moving on to the Power
ON from the status of normal standby.