8.5 PC Adjust Control Command
8.5.1 CF_FSYNC Command
Command “CF_FSYNC_%1”[CR]
%1
“0000~0031” --------------- Directly select Fine Sync setting value
“UP” -------------------------- Current Fine Sync setting value + 1
“DN” -------------------------- Current Fine Sync setting value - 1
Details
Set Fine Sync value of PC signal
The value set by this command will not be saved to projector. Therefore, when
turning into Standby status or ALL is OFF, the value returns to original setting.
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable “Error Code”[CR]
8.5.2 CF_TDOTS Command
Command “CF_TDOTS_%1”[CR]
%1
“mmmm~nnnn” --- Directly select Total Dots setting value
“mmmm” shows minimum value, it is current Display Dots value +
Horizontal
Position value.
“nnnn” shows maximum value, which is not over 150MHz.
“UP” -------------- Current Total Dots setting value + 1
“DN” -------------- Current Total Dots setting value - 1
Details
Set Total Dots of PC signal
The value set by this command will not be saved to projector. Therefore, when
turning into Standby status or ALL is OFF, the value returns to original setting.
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable “Error Code”[CR]
8.5.3 CF_CLAMP Command
Command “CF_CLAMP_%1”[CR]
%1
“mmmm~nnnn” ---- Directly select Clamp setting value
“mmmm” shows minimum value, fixed-value “0001”.
“nnnn” shows maximum value: it depends on input signal.
“UP” ------------------ Current Clamp setting value + 1
“DN” ------------------ Current Clamp setting value – 1
Details
Set Clamp value of PC signal
The value set by this command will not be saved to projector. Therefore, when
turning into Standby status or ALL is OFF, the value returns to original setting.
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable “Error Code”[CR]