Canon_LV_Series_Command_List

32/52
Data Portion Contents
-----------------------------------------------------------------
DATA01 to 02 Results
0000H : Normal
0000H Other : Error
Response: At the time of a failure
A3H 10H 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2) (*4) (*3)
Supplement:
Command example:
* Setting Brightness to 10
03H 10H 00H 00H 05H 00H FFH 00H 0AH 00H 21H
* Setting Brightness to -10
03H 10H 00H 00H 05H 00H FFH 00H F6H FFH 0CH
028. KEYSTONE ADJUST
**********************************************************************
Function:
This command adjusts the Keystone.
Command:
03H 10H 00H 00H 05H 15H 01H DATA03 to DATA05 CKS
(*3)
Data Portion Contents
-----------------------------------------------------------------
DATA01 15H fixed
DATA02 01H fixed
DATA03 Adjustment mode
00H : Absolute value specification
01H : Relative value specification
DATA04 Adjustment value ( Lower ranking 8 bits )
DATA05 Adjustment value ( Upper ranking 8 bits )
Response: At the time of a success
23H 10H 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2) (*3)
Data Portion Contents
-----------------------------------------------------------------
DATA01 to 02 Results
0000H : Normal
0000H Other : Error