Canon_LV_Series_Command_List

50/52
01H : Lamp2
DATA02 Unit (!4)
00H : Second
01H : Reserved
02H : Hour
DATA03 Item
00H : Lamp counter (!2)
01H : Lamp counter (!3)
04H : lamp remaining amount until lamp warning message
( 100% to -X%(!1) )
05H : Lamp counter (Normal mode)
06H : Lamp counter (Eco mode)
08H : Remaining time until lamp warning message starts
to appear (in terms of specified values)
09H : Remaining time until lamp warning message starts
to appear (in terms of Normal mode values)
0AH : Remaining time until lamp warning message starts
to appear (in terms of Eco mode values)
10H : Remaining time until inhibition of lamp usage
(in terms of specified values)
11H : Remaining time until inhibition of lamp usage
(in terms of Normal mode values)
12H : Remaining time until inhibition of lamp usage
(in terms of Eco mode values)
Response: At the time of a success
23H 9BH 01H xxH 07H DATA01 to DATA07 CKS
(*1) (*2) (*3)
Data Portion Contents
-----------------------------------------------------------------
DATA01 same values as DATA01 of the command
DATA02 same values as DATA02 of the command
DATA03 same values as DATA03 of the command
DATA04 to 07 Acquired information
Response: At the time of a failure
A3H 9BH 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2) (*4) (*3)
Supplement:
* In case of acquiring lamp's use of hours
03H 9BH 00H 00H 03H 00H 00H 01H CKS
Example of acquisition
DATA04 DATA05 DATA06 DATA07 : lamp's use of hours
50H 46H 00H 00H : 18000 seconds
Lamp Usage = 18000 / 3600 = 5 hour