User Guide

Chapter 1
 
1-2
1.1 Periodically Replaced Parts
1.1.1 Overview
0002-9397
Some parts of the machine must be replaced on a periodical basis for the machine to maintain a specific level of
performance. They must be replaced regardless of the presence/absence of external changes or damage, as the
performance of the machine will be considerably affected once they fail.
If possible, plan any replacement to coincide with a scheduled visit.
The intervals indicated may vary depending on the site environment and user habit.
- Checking the Timing of Replacement
The timing of replacement may be checked using the following service mode items:
- Copier
COPIER>COUNTER>PRDC-1
- Accessory
COPIER>COUNTER>PRDC-2
1.1.2 Reader Unit
0000-9633
The machine's reader unit does not have parts that must be replaced on a periodical basis.
1.1.3 Printer Unit
0002-9400
T-1-1
as of February 2004
Ref. Parts name Parts No. Q'ty Interval Remarks
1 Ozone filter
FC5-2486-
000
1
250,000
images*
(*)
2 Toner filter
FL2-0554-
000
1
250,000
images*
(*)
3 Primary charging wire
FB4-3687-
000
AR
500,000
images*
(*)
4 Charging wire cleaner 1
FL2-2427-
000
1
500,000
images*
(*)
5 Charging wire cleaner 2
FL2-2428-
000
1
500,000
images*