User Guide
Action to Take in Response to Error Codes
• When the self diagnosis function has turned ON and an error code has been indicated, you can reset
the machine by turning its power switch OFF once.
E000, E001, E002, E003, E004, and E007–01, and E717 is not reset by turning OFF the power switch;
this is to prevent the user from casually resetting the machine, since such could sometimes damage
the machine.
Resetting
1) Start service mode by pressing the service switch and then pressing the * key twice.
2) Press ‘FUCNTION’ on the LCD to highlight; then, press the OK key.
3) Press ‘ERROR’ on the LCD to highlight; then, press the OK key.
• This will automatically remove and then supply power.
• In the case of ‘E202’, the keys on the control panel will be locked without indicating an error code; use
‘ERR’ under ‘DISPLAY’ in service mode (*1*) if this is the case.
• In the case of ‘E007’, turning off and then on the main power switch will activate film recovery mode
(‘FILM_COMEBACK’ in service mode *4*), thereby resetting the machine after returning the film to its
correct position.
If the film fails to return to the correct position after executing this recovery mode, ‘E007-01’ will be indi-
cated. If this happens, replace the fixing assembly or take appropriate measures, return the film to its
correct position, and execute ‘ERROR’ in service mode (*4*).
Note that ‘E007-01’ in service mode will be indicated as ‘E007’, omitting the last two digits under ‘ERR’
of ‘DISPLAY’ in service mode (*1*).
After the film has returned to normal position following the execution of 'FILM COMEBACK', be sure
to turn OFF and then ON the main power supply without touching the other keys.
3–265
COPYRIGHT © 1996 CANON INC. CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3. OPERATIONS AND TIMING