User Guide

COPYRIGHT © 1996 CANON INC. CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3–200
3. OPERATIONS AND TIMING
Index
(leading edge)
Copyboard glass
-+
P147-2
4. Registration-Related Items
CANCEL
+
OK
*3* ADJUST 04
H-ADJ : xxxxx <– (xxxxx)
V-ADJ : xxxxx <– (xxxxx)
RESIST : xxxxx <– (xxxxx)
RSIDE-SENSHP : xxxxx <– (xxxxx)
PVE-OFST : xxxxx <– (xxxxx)
Settings
0~500
0~1000
0~1000
Item
H-ADJ
V-ADJ
RESIST
Remarks
unit:1mm
(approx.; at 23)
unit: 1mm
(approx.; at 23)
Standard:
2.5 ±1.0 mm
Index (rear)
Copyboard glass
CCD
-+
Description
Use it to fine-adjust the CCD reading start
position (main scanning direction; book
mode)
A higher setting shifts the read start position
to the right.
Use it to adjust the image reading start posi-
tion (sub scanning direction).
A higher setting delays the registration ON
timing.
Use it to adjust the registration clutch ON
timing (leading edge margin).