User Guide

Chapter 2: Service Error Codes
2-120
Cause Remedy
##776 [ TX ] In ECM transmission, a signal other than
ERR was received after transmission of
EOR-MPS
Record the protocol on a DAT or MD, and
have it analyzed by the local Canon office
and/or Technical Center.
• The procedure signal is faulty.
Cause Remedy
##777 [ TX ] In ECM transmission, DCN was received
after transmission of EOR-MPS
Increase the transmission level
*1
so that the
other party may receive EOR-MPS cor-
rectly.
Adjust the NL equalizer
*2
so that the other
party may receive EOR-MPS correctly.
Add an echo protect tone to the V.29 mo-
dem signal for transmission
*8
.
• Transmit once again.
The line condition is poor, and the other
party cannot receive EOR-MPS correctly.
The Stop key was pressed during a com-
munication.