DP-V1710, DP-V1711 Instruction Manual

OSD Menu
80
Sub Menu Setting Options (Bold: factory default)
Pixel Value Check
7
When [Gamma/EOTF] [SMPTE ST 2084 (PQ)] or [Hybrid Log-Gamma]
The luminance and RGB value of the speciļ¬ed pixel (cursor) position are measured and displayed.
The pixel value check can be used when the resolution is [4096x2160], [3840x2160], [2048x1080] or
[1920x1080].
Enable On, Off Switches the pixel value check On, Off.
H Position 1 to 4096 (960) Sets the pixel position (horizontal).
V Position 1 to 2160 (540) Sets the pixel position (vertical).
Reset Position Normal
Around Peak
Luminance
Sets operation when the RESET button is pressed.
[Normal]: Resets the value to the default value.
[Around Peak Luminance]: Moves closer to the area of peak luminance
inside the display image.
Frame Luminance Monitor
7
When [Gamma/EOTF] [SMPTE ST 2084 (PQ)] or [Hybrid Log-Gamma], "Max./Ave. Luminance"
for the entire screen (frame) is displayed. For other conditions, "Max./Ave. Gradation Values"
is displayed. The frame luminance monitor can be used when the resolution is [4096x2160],
[3840x2160], [2048x1080] or [1920x1080].
Current value for peak luminance
(cumulative maximum value)
Current value for average luminance
(cumulative maximum value)
Peak luminance
Average luminance
Enable On, Off Switches the frame luminance monitor On, Off.
Reset Resets the displayed content.
Peak Luminance Rise
Reference
0 to 1000 (400) Sets the Peak Luminance Rise Reference value. (10 cd/m
2
)
Ave. Luminance Rise
Reference
0 to 1000 (200) Sets the Ave. Luminance Rise Reference value. (10 cd/m
2
)
Test Pattern
8
White (1023),
White (940),
Gray, Black (64),
Black (0), Ramp,
Color Bars,
Color Bars (PQ Full),
Color Bars (PQ Limited),
Color Bars (HLG),
PLUGE, PLUGE (PQ/HLG)
,
Off