<Cause>The cartridge is not installed correctly outside of the
cartridge replacement position.
<Suspected Parts> Cartridge, control board, carriage board,
carriage ribbon cable
<Measures>
8. Cartridge
Displaced Error
Reinstall the cartridge
END
Ye s
No
Error displayed?
2. Replace the control
board
3. Replace the carriage
ribbon cable
4.Replace the carriage
board
1.Replace the
cartridge