Cut Sheet

C213UNVxx
x
APPLICATION and PERFORMANCE SPECIFICATION
Description: Electronic compact fluorescent ballast(s) for (2/1) CFQ/M13W/G24q or (2/1) CFQ/M13W/GX24q
or (2/1) CFS16W/GR10q (2D) or (2/1) CFS10W/GR10q (2D) 4 pin lamps
or
(2/1)
CFS16W/GR10q
(2D)
or
(2/1)
CFS10W/GR10q
(2D)
4
-
pin
lamps
• Line Voltage: 120vac to 277vac, ±10%, 50-60Hz • Programmed Rapid Start
• High Power Factor • Series Lamp Connection
Line Input Nominal Ballast Power Crest
Volts Type # Watts Line Amps Factor Factor Factor
120 CFQ13W 2 30 0.26 1.00 > .98 < 10% <1.7
277 CFQ13W 2 30 0.11 1.00 > .98 < 10% <1.7
120
CFQ13W
1
18
015
100
>98
<1 7
Lamp
THD
C213UNV
Model
120
CFQ13W
1
18
0
.
15
1
.
00
>
.
98
<1
.
7
277 CFQ13W 1 18 0.07 1.00 > .95 < 15% <1.7
120 CFM13W 2 30 0.26 1.00 > .98 < 10% <1.7
277 CFM13W 2 30 0.11 1.00 > .98 < 10% <1.7
120 CFM13W 1 18 0.15 1.00 > .98 < 10% <1.7
277 CFM13W 1 18 0.07 1.00 > .95 < 15% <1.7
120 CFS10W 2/1 26/15 .22/.12 1.02 > .98 <10% <1.7
277 CFS10W 2/1 26/15 .10/.06 1.02 > .95 <15% <1.7
120 CFS16W 2/1 33/19 .28/.15 .95 > .98 < 10% <1.7
C213UNV
C213UNV
C213UNV
C213UNV
C213UNV
277 CFS16W 2/1 33/19 .12/.07 .95 >.95 <15% <1.7
Application and Performance Specification Information Subject to Change without Notification
Performance: Safety:
• Meets ANSI Standard C82.11 • No PCB's
• Meets FCC Part 18 (Non-Consumer), Limits for EMI/RFI
C
UL
US
listed
(Class P)
• Operating Frequency Range: 50-60 kHz Type 1 Outdoor, Type CC, Type HL
Auto-Reset Shutdown Circuit per NEMA Recommendations
- Both lamps should be replaced at end of life
C213UNV
- Lamp relights upon insertion in socket
• Suitable for use in air handling spaces when NEC wiring guidelines are followed
• ME version: Input Terminals L N G intended for one supply connection only
Application: Physical Parameters:
• Minimum Starting Temperature: 0° F, -18° C
Overall Length:
4.94"
• Maximum Case Temperature (@ t
c
):
167° F, 75° C Width: 2.31"
• Sound Rated: A Mounting: 4.61"
Lead configuration:
Height:
100
"
Lead
configuration:
Height:
1
.
00
x
xx = ME - Multi-Exit Weight: 0.57 lbs
or
MES - Multi-Exit with Studs (2" on center) Qty/Carton: 20
• Remote Mounting 20 feet Color: ME/MES-White
• 13W applications also operate on 125VDC input (+)L (-)N Can Material: Metal
Warranty:
Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from
defects in material or workmanship for a period of 5 years from date of manufacture when properly installed
and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance.
Manufactured in North America
Ballast has plug in
Install in accordance with wire trap connectors.
the National Electrical Code. Use 18 AWG solid copper wire,
stripped to 3/8".
Ballast Must be Grounded.
Use External Ground Wire
Use
External
Ground
Wire
.
Black
Green
White
One Lamp
Application
Red
Blue
Red
Blue
Black
Green
White
Reds
Yellows
Blues
Two Lamp
Application
1-800-BALLAST www.unvlt.com February 2014