Indoor unit must be installed with Category III vent pipe in accordance with vent
supplier/manufacturer in accordance with local code.
A. BACK INSTALLATION
1. Insert the vent pipe through the installation holes in the wall with the
terminal sticking out.
2. Connect the elbow to the vent pipe and water heater, moving straight
backwards until the expansion screws go into the holes of the water heater.
Screw the nuts tight (pay attention to the direction of the elbow.)
B. SIDE INSTALLATION
1. Aim the holes in the water heater onto the expansion screws, hang it up
and screw the nuts tightly.
2. Put the vent pipe through the holes in the wall, and connect the elbow with
the water heater and vent pipe.
C. VERTICAL INSTALLATION
Please refer to local installation professional or venting manufacturer:
The installation hole in the wall needs to be sealed by fire-retardant materials
or wall thimble, making sure the water heater is tight and will not come off.