TECHNICAL INFORMATION MANUAL Revision 0.
Visit the Hadron R4320C web page, you will find the latest revision of data sheets, manuals, certifications, technical drawings, software and firmware. All you need to start using your tag in a few clicks! Scope of Manual The goal of this manual is to provide the basic information to work with the Hadron R4320C Reader. Change Document Record Date 23 Oct 2018 Revision 0 12 Mar 2019 0.1 01 July 2019 0.2 04 July 2019 0.
at their own expense. The authority to operate this product is conditioned by the requirements that no modifications be made to the equipment unless the changes or modifications are expressly approved by CAEN RFID. Preliminary Product Information This document contains information for a new product. CAEN RFID reserves the right to modify this product without notice.
Index Scope of Manual ...........................................................................................................................................................................2 Change Document Record ............................................................................................................................................................2 Reference Document .....................................................................................................................
List of Tables Tab. 2.1: Hadron R4320C Technical Specifications ................................................................................................................................10 Tab. 2.2: Hadron R4320C Supply and Interface Connector Pinout ........................................................................................................11 Tab. 2.3: Hadron R4320C Supply and Interface Connector Electrical Characteristics...................................................................
1 INTRODUCTION Product Description © The Hadron (Model R4320C), embedded module of the easy2read product line, is a RAIN RFID multiregional compact reader for high performances applications. With programmable output power from 10dBm to 31.5dBm, the reader reaches top reading performances being able to detect RAIN tags from a distance of 9 m (30 feet) depending on the antenna and the tag used.
The Mod. R4320CEVB - R4320C Hadron Evaluation Board allows managing the Hadron R4320C reader directly via USB and RS232 interfaces. This board is particularly suited for Hadron R4320C reader evaluation and SW development purpose. Fig. 1.
Development Kit A development kit with adapter, antennas, cable and demo tags is available: Fig. 1.4: R4320CXDK: Accessories kit with adapter, antennas, cable and demo tags The kit includes: • n. 1 WR4320CXEVBX R4320C - Hadron - Evaluation Board • n.1 Circular Polarized Quadrifilar Antenna MMCX (ETSI or FCC) • n. 1 Set of Labels • n. 1 A927Z Temperature Logger Tag • n. 1 RT0005 Temperature Logger Tag • n. 1 WALIM0000002 Power Supply for Hadron R4320C Adapter Board • n.
Ordering Options Code Reader WR4320CXAAAA WR4320CXDKEU Development kit WR4320CXDKUS WR4320CXEVBX WANT020XMMCX Accessories WANT021XMMCX WALIM0000002 Description R4320C - Hadron - High Performance 4-port Embedded UHF RFID Reader Hadron - ETSI Dev Kit with antenna, interface, power supply and tags (reader not included) Hadron - FCC Dev Kit with antenna, interface, power supply and tags (reader not included) R4320C - Hadron - Evaluation Board ANT020/MMCX - Quad - Circular polarized quadrifilar antenna (ETSI)
2 HADRON R4320C Technical Specifications Table Frequency Range RF Power Output Power Accuracy Antenna VSWR Requirement Antenna Connectors Frequency Tolerance Number of Channels Standard Compliance Digital I/O Forward Link Characteristics Return Link Characteristics Connectivity Dimensions Power Consumption (max) DC Power Operating Temperature Weight − 865.600÷867.600 MHz (ETSI EN 302 208 v3.1.1) − 902÷928 MHz (FCC part 15.247) Programmable from 10dBm to 31.
External Connections The location of the connectors is shown in Fig. 2.1: Hadron R4320C Technical Drawings page 11. Their part numbers are listed here below: Antenna Ports: RF Coax Connector Huber+Suhner type 82_MMCX-S50-0-2/111_K (to be used with Huber+Suhner type 11_MMCX-50-1-1/111_O) MOLEX Connector: PCB Header Molex type 53261-1571 (to be used with Molex Type 51021-1500 + 15pcs crimp terminal type 50058-8100) Fig. 2.
The RXD/TXD pins are used to communicate with the R4320C board via UART port; to establish a link with the device 2 you must configure your COM port as follows : Baud rate: 115200 Parity: None Data bits: 8 Stop bits: 1 Flow Control: none 5V USB signal is used to sense the presence of an USB host device connected to the module and not for supply the device. This pin shall be left unconnected for UART operation.
Power supply connection In the following schematic suggested R4320C power supply connection is shown. The use of a resettable fuse (F1) is recommended since R4320C does not provide internal current limitation protection. Diode D1 avoid damage to the reader in case of reverse polarity connection. Fig. 2.2: Hadron R4320C Power Supply Connection General purpose I/O connections The GPIO0-GPIO3 pins are 4 general-purpose bidirectional pins.
Shutdown pin R4320C SHUTDOWN pin allows to set the module in power off mode (current consumption less than 1mA) and can be used also for manual reset operation. SHUTDOWN pin is pulled-down by an internal resistor. Fig. 2.4: Hadron R4320C SHUTDOWN pin connection Communication interface selection The communication with Hadron R4320C module can be performed via UART or USB interface.
Fig. 2.5: Hadron R4320C RS232 Connection FW Recovery/Upgrade ERASE pin is reserved and shall be used only to perform the microcontroller FW recovery/upgrade procedure during which it must be forced at high level (3.3V or 5V). In the following diagram a manual recovery mechanism is shown: in order to perform the R4320C boot recovery the jumper JP shall be inserted, then R4320C module shall be switched on for 5s at least.
Antenna port specifications In the following table the pinout of R4320C antenna ports is shown. Pin # INNER OUTER Function RF OUT GND Direction OUT - Description RF output Ground Tab. 2.4: RF Port Pinout Parameter RF output power (nominal) Min 10 10 Output power vs. power setting accuracy RF port impedance Recommended antenna VSWR Typ. Max 1400 31.5 ±1 50 2:1 Unit mW dBm 5 dB Ω - Tab. 2.
2) Power on the board for at least 5s. 3) Remove the power supply. 4) Place the jumper in the original position. 5) Connect the USB or the RS232 cable to the board. 6) Power on the board. 7) Launch the R4320C Upgrade Tool and click on Next button. 8) Select the COM port related to the device (the COM address of RS232 in case of use of the serial interface, the Bossa Program Port assigned by OS in case of use of the USB interface).
12) Switch off the module; at the next power on the device will be operating with the new FW image.
3 HADRON R4320CEVB Technical Specifications Table Digital I/O USB Port RS232 Port LED display Dimensions Electrical Power Operating Temperature Four I/O lines 3.3 V out @ 3mA, 5 V tolerant USB B female connector USB 2.0 device It appears as R4320C Virtual COM Port device; drivers for all Windows OS Baudrate: 115200 Databits: 8 Stopbits: 1 Parity: none Flow control: none 9.6÷115 kbit/s data rate (settable) RED: Power GREEN: GPIO[0..
Installation Notice Fix the Hadron R4320C reader to the R4320CEVB board using 3 M2x12 countersunk screws and 3 M2 screws nuts and connect the Molex connectors. The reader case shall be kept electrically isolated via thermal sildpad from the ground plane. The correct way to connect the R4320C module to the R4320CEVB evaluation board is shown in the following picture: Fig. 3.
Technical drawings The following drawing shows the R4320CEVB components position. Fig. 3.
Electrical schematic The electrical schematic of the Hadron R4320CEVB is shown in the following figure: Fig. 3.
External Connections Please refer to § Fig. 3.3: Hadron R4320CEVB Technical Drawing page 21. J1: free PTH pads for GPIO external connection − J1-1 = GPIO0 (in/out) − J1-2 = GPIO3 (in/out) − J1-3 = GPIO1 (in/out) − J1-4 = ERASE − J1-5 = GPIO2 (in/out) − J1-6 = Not Connected J2: Power Supply connector: central pin (2.54mm diam.) is the positive terminal. J3: RS232 DB9 female connector J4: USB Type B port J5: Connector for FW Recovery/Upgrade Procedure LEDs Please refer to § Fig. 3.
4 REGULATORY COMPLIANCE FCC Compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
j. If the FCC ID is not visible when the module is installed inside another device, the OEM integrator shall apply a label in a visible area on his product with the following statement: Contains Transmitter Module FCC ID: UVECAENRFID027 or Contains FCC ID: UVECAENRFID027 RoHS EU Directive The Hadron R4320C RFID reader is compliant with the EU Directive 2011/65/CE on the Restriction of the Use of certain Hazardous Substances in Electrical and Electronic Equipment (RoHS2).