Owner manual

300/300-P Series Industrial Grade SSD Product Manual v2.0Cactus Technologies
®
31
Table 5-27. Extended Error Codes
Extended Error Code Description
01h Self Test OK (No Error)
03h Write Failed
09h Miscellaneous Error
11h Uncorrectable ECC Error
18h Corrected ECC Error
20h Invalid Command
21h Invalid Address
27h Write Protection Violation
5.1.16. Seek-7XH
The Seek command in Table 5-28 is eectively a NOP command to the drive although it does
perform a range check of cylinder and head or LBA address and returns an error if the address is
out of range.
Bit -> 7 6 5 4 3 2 1 0
Command (7)
7XH
C/D/H (6)
1 LBA 1 Drive Head (LBA 27-24)
Cyl High (5)
Cylinder High (LBA 23-16)
Cyl Low (4)
Cylinder Low (LBA 15-8)
Sec Num (3)
X (LBA 7-0)
Sec Cnt (2)
X
Feature (1)
X
Table 5-28. Seek
5.1.17. Set Features-EFH
Table 5-29. Set Features
Bit -> 7 6 5 4 3 2 1 0
Command (7)
EFH
C/D/H (6)
X Drive X
Cyl High (5)
X
Cyl Low (4)
X
Sec Num (3)
X
Sec Cnt (2)
X
Feature (1)
Feature
The Set Features command in Table 5-29 is used by the host to establish or select certain features.
Table 5-30 denes all features that are supported.