Particular safety instructions
BVS 13 ATEX E104X / E087X
4.2 Installation locking wire for PE99
and PX03
Danger!
Risk of explosion when opening the device.
Open device only when no Ex atmosphere is present.
Prior to start-up, secure the transparent cap against being opened
without tools by using the enclosed locking wire.
Fastening element
Screw
Circlip
Locking wire
Transparent cap
Fig. 4: Installation locking wire
Procedure:
Push locking wire through the bore of the transparent cap.
Push locking wire through fastening element and pull it tight.
Tighten the screw on the fastening element.
4.3 Adaption set - installation note
Danger!
Risk of explosion if incorrect adaption set is used.
Only use suitable adaption set.
The degree of protection required for ignition degree of pro-
tection intrinsic safety "i", is only guaranteed in connection
with suitable adaption sets.
Attachment Adaption set series
FA03 ELEMENT
FA05 Classic
Tab. 3: Attachment and adaption set
The order designations for the adaption sets can be found in
the "Order table adaption sets" in the data sheet for Type 8697.