User Manual
Operating Instructions Type 0407
Design:
2-way solenoid valve, internally piloted, normally closed
(Circuit function A).
Seal Materials and Fluids handled:
See Table1.
Fluid and Ambient Temperature:
See Table 1.
Pressure Range:
Maximum inlet pressure see label on valve.
A pressure differential between inlet port and outlet port is not
required.
Installation:
Before installing valve ensure that piping etc. is free of foreign
matter (metal fillings, seal material, welding scale etc.). PTFE
tape is recommended for sealing ports. Arrow on valve body
gives flow direction. Installation as required but preferable
with coil uppermost. Installation in this position tends to
prevent foreign matter remaining in pilot valve (increased
life). A strainer upstream of valve, protects against effects of
foreign matter. Do not put any loads on coil unit. Pipework
should be supported such that valve body is not under strain.
Do not allow a pipe-end or sealing material to block the pilot
bore within the valve outlet. Inlet and outlet of valve must be
fullbore and pipework unrestricted.
Marking (example):
Body Material
BR = Brass
Seal Material
EPDM = EPDM
FKM = FKM
EG = PTFE Seat and Graphite seal
Circuit Function
A = Normally Closed
Recorder No.
Voltage / Frequency / Power Consumption
Maximum Pressure
Operating Instructions 1212/09_EU-EN_00893147
Table 1 Seal materials
Fluid Tempera-
tures [°F]
Ethylene (A)
Propylene
PTFE (G)
Air Fluid T.
Ambient
+ 32 to + 275
+ 14 to + 130
+ 32 to + 356
+ 14 to + 130
Water Fluid T.
Ambient
+ 50 to + 212
+ 32 to + 130
+ 32 to + 212
+ 32 to + 130
Neutral
gas
Fluid T.
Ambient
+ 32 to + 275
+ 14 to + 130
+ 32 to + 356
+ 32 to + 130
Light oil Fluid T.
Ambient
+ 50 to + 194
+ 14 to + 130
+ 50 to + 194
+ 14 to + 130
LP-gas Fluid T.
Ambient
+ 32 to + 140
+ 14 to + 130
+ 32 to + 140
+ 14 to + 130
Steam Fluid T.
Ambient
+ 212 to + 275
+ 14 to + 130
+ 212 to + 356
+ 14 to + 130
Voltage 12V or 24V
UL / UR valid with
class 2 power supply only