BUNN refresh™ INSTALLATION & OPERATING GUIDE BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and manual updates.
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCR/MCP/MCA single cup brewers, thermal servers and ThermoFresh® servers (mechanical and digital) 1 year parts and 1 year labor. 2) All other equipment - 2 years parts and 1 year labor plus added warranties as specified below: a) Electronic circuit and/or control boards - parts and labor for 3 years.
CONTENTS Warranty......................................................................................................................... 2 User Notices................................................................................................................... 3 Initial Set-Up & Electrical Requirements......................................................................... 4 CE Requirements............................................................................................................
INITIAL SET-UP CAUTION: The dispenser is very heavy! Use care when lifting or moving it. Use at least two people to lift or move the dispenser. Place dispenser on a sturdy counter or shelf able to support at least 125 lbs. (57 kg). The dispenser is designed for indoor use only, in ambient temperatures ranging from 50°F to 90°F (10°C to 32°C). Avoid locating the machine where it will be subject to direct sunlight or exposed to other external heat sources.
PLUMBING REQUIREMENTS The dispenser must be connected to a COLD WATER system with an operating pressure between 30 and 100 psig (.207 and .690 mPa). This water source must be capable of producing a minimum flow rate of 3 fluid ounces (88.7 milliliters) per second. A shut off valve should be installed in the line that will supply the dispenser. A water filter has been included with the dispenser.
FILLING THE WATER BATH 1. Plug the dispenser into an electrical outlet and turn on the water supply to the dispenser. 2. Flip the dispense switch to ON. The water bath will begin to fill. The water bath will fill and automatically shut off when the water bath is full. 3. Check the sight glass to confirm that the water bath is full (See Figure 5). Once the water bath is full, flip the compressor switch to ON.
CHANGE WATER FILTER CARTRIDGE WARNING The water filter cartridge will need to be changed after 4,500 gallons of use. When the water usage gets close to 4,500 gallons, the blue LED will flash slowly to indicate that it is nearly time to replace the water filter cartridge. When the water usage exceeds 4,500 gallons, the blue LED will flash rapidly to indicate that it is time to replace the water filter cartridge.
ELECTRICAL WIRING SCHEMATIC DIAGRAM 120V TRANSFORMER BLU L O A D WHT/BLU A B A B BLK GRN WHT L1 N BLK BLK L I N E BLK WHT COMPRESSOR MOTOR LIMIT THERM. PTC ASSY 1 BLU/BLK MOTOR WHT WHT RED/BLK WHT RECIR.
FUNCTION INDICATORS Circuit Board LED Indicators LED # LED Color Function/Description 1 Red - On Indicates that the bath temperature is above 34˚ F. 1 Red - Flashing The compressor is in a 6 minute delay period when slowly flashing. 2 Red - Flashing When the bath thermistor circuit is open, the LED’s (1 & 2) will flash one time every three seconds. The compressor will not run under this condition.
WATER SUPPLY INLET WATER SOLENOID WATER PRESSURE BOOSTER PUMP WATER PRESSURE REGULATOR DOUBLE CHECK VENT TO ATMOSPHERE 10 COIL PRODUCT WATER BATH WATER BATH FILL SOLENOID RECIRC PUMP INTERNAL EXTERNAL RECIRC CONDUIT RECIRC LOOP RECIRC LOOP WATER CHECK VALVE CARBONATOR CO2 CHECK VALVE PRIMARY CO2 PRESSURE REGULATOR STILL WATER FLOW VALVE SPARKLING WATER FLOW VALVE SECONDARY CO2 PRESSURE REGULATOR CO2 FITTING CO2 SUPPLY STILLWATER SOLENOID VALVE SPARKLING WATER SOLENOID VALVE FLOW LA
COOLANT SCHEMATIC DIAGRAM 11 52373.
BUNN refresh Install Pictorial 2-gauge Pressure Regulator Kit (Sold Seperately) NOTE: For proper air circulation and functionality, leave 4” of clearance on both sides, and 6” of clearance at the top and back of the machine. CO2 Supply Set at 120psig Main On/Off Water Valve 1/4” Tube Included w/Regulator Kit Operating Water Pressure Min. 30 psi Max.