Installation Manual

2
Product information
SU54/5, SU80/5, SU100/5 – 6 720 808 532 (2013/08) 7
2.7 Physical and connection dimensions
Fig. 4 Physical and connection dimensions
6 720 805 397-03.4TT
F
G
H
I
K
J
E
A
L
M
D
E
F
H
I
J
G
A
C
C
B
D
SU 54/5 SU80/5, SU100/5
1"
1"
1"
1"
¾"
¾"
1"
1"
1"
1"
¾"
¾"
Item Description Unit SU54/5 SU80/5 SU100/5
A Diameter inch
(mm)
21-3/4
(550)
26-3/8
(670)
26-3/8
(670)
B Minimum floor weight carrying capacity Ib
(kg)
628
(284)
893
(405)
1122
(509)
C Clearance off floor inch
(mm)
1/2
(12.5)
3/8 - 3/4
(12.5)
3/8 - 3/4
(12.5)
D Overall height inch
(mm)
60-1/4
(1530)
58-7/8
(1495)
72-1/4
(1835)
E Height, cold water inlet inch
(mm)
3-1/4
(80)
3-1/8
(80)
3-1/8
(80)
F Height, tank return inch
(mm)
10-1/2
(265)
12-1/2
(318)
12-1/2
(318)
G Height, sensor well for temperature sensor inch
(mm)
17-1/8
(433)
31-1/5
(617)
24-3/10
(793)
H Boiler flow height inch
(mm)
21-7/8
(553)
28-1/2
(722)
35-3/8
(898)
I Height, recirculation connection inch
(mm)
27-3/4
(703)
35-1/2
(903)
45
(1148)
J Height, DHW outlet inch
(mm)
56.4
(1399)
53-3/8
(1355)
66-3/4
(1695)
K Minimum room height for anode replacement inch
(mm)
74-1/4
(1880)
72-7/8
(1850)
82-3/4
(2100)
L Weight (empty) lb
(kg)
160.9
(73)
231.5
(105)
282.2
(128)
M Weight (full) lb
(kg)
601.9
(273)
892.9
(405)
1142
(518)
Table 6 Physical and connection dimensions