USERS INFORMATION MANUAL Heating & Cooling Systems MODEL TSTATBBPS101 PROGRAMMABLE DIGITAL THERMOSTAT NOTE TO INSTALLER: This manual must be left with the equipment user.
Table Of Contents FRONT PANEL DISPLAY QUICK START Set the clock and go BASIC OPERATION PROGRAMMING 4 Time Periods ADVANCED SETUP ABOUT ADVANCED OPERATION WARRANTY 2 3 5 6 8 11 14 18 CAUTION Follow Installation Instructions before proceeding. SET THERMOSTAT TO MODE “OFF” PRIOR TO CHANGING SETTINGS IN SETUP OR RESTORING FACTORY DEFAULTS.
Front Panel 6:03 Su AUTO 68 Am 70 Backlit LCD Display Warmer or + Button o COOL 67 HEAT o Cooler or - Button Mode Button Heat or Cool Indicator Red = Heat, Green = Cool Programmable Thermostat 6:03 S AUTO FAN FAN OUTSIDE 70 o COOL 67 HEAT o VACATION PROGRAM SET CLOCK BACKLIGHT EMERGENCY HEAT Page 2 68 Am MODE PROGRAM SET CLOCK
Display 9 2 1 : 12:00 1 8 6 88 Am ProgramOn Setup Start Locked Pm 88 AUTO OFFNight 5 Morning Day Evening 7 Fan On o COOL 88 HEAT o 4 1 1 4 3 1 Mode Indicators Selects the operation mode of the equipment. HEAT - indicates the heat mode. COOL - indicates the air conditioning mode. AUTO - indicates the system will automatically changeover between heat and cool modes as the temperature varies. OFF - indicates the entire system is turned off.
Display 5 Morning, Day, Evening & Night Indication Indicates the program time period. Page 8-10. 6 Setup Indication Indicates the thermostat is in the programming mode. Page 6. 7 Fan Operation Indication Fan On - indicates constant, continuous fan operation. When Fan On is not lit - indicates the fan will only operate when necessary to heat or to cool. Page 7. 8 Locked Indication Locked appears after the right combination of buttons are pressed, rendering the buttons inoperative. Page 16.
Quick Start Set the Clock and Go Press the Set Clock button to enter Setup screens. SET CLOCK I2:00 AM Setup I During Setup & Programming: Pressing the Mode button selects different flashing items. (Represented in dark black) Pressing the Up and Down buttons will modify the flashing selection. Press Setup Mo 2 To adjust the clock or Day use MODE buttons. Press the SET CLOCK SET CLOCK button to return to normal operation.
Basic Operation Select Mode : 12:00 The HEAT setting indicates the temperature the room has to reach before the furnace will turn on to heat the room. The COOL setting indicates the temperature the room has to reach before the air conditioner will turn on to cool the room. 70 70 70 70 70 : 12:00 : 12:00 AUTO will automatically select heat or cool based on room temperature demand. Program On will activate the stored timer operation.
Basic Operation Select Desired Temperature : 12:00 AUTO 72 70 Pm o In any mode, adjust the desired Set Temperature with COOL 69 HEAT o buttons. Pressing the Up or Down buttons in Auto mode will adjust both the heat and cool set temperatures simultaneously. Pressing the Up or Down buttons in Heat or Cool modes will adjust only the heat or cool set temperature. Fan Operation : 12:00 Fan On Press FAN 65 Pm 85 o COOL 55 HEAT o Fan On indicates constant fan operation.
Programming Press PROGRAM 4 Time Periods Press the PROGRAM button to enter time period programming. Use the back cover Programming Worksheet to help with this section. 7 :30 Am Start Adjust the start time for Morning. Morning Press MODE 7 :30 Am Adjust the cooling setpoint for Morning. (35 - 99 ) 74 o COOL Morning Press MODE 7 :30 Am Adjust the heating setpoint for Morning.
Programming 4 Time Periods I0 :30 Am Start Adjust the start time for Day. Day Press MODE I0 :30 75 Am Adjust the cooling setpoint for Day. o COOL (35 - 99 ) Day Press MODE I0 :30 75 Am Adjust the heating setpoint for Day. (35 - 99 ) o COOL 73 HEAT o Day 5 :30 Pm Press MODE Start Adjust the start time for Evening. Evening Press MODE 5 :30 Pm Adjust the cooling setpoint for Evening.
Programming 4 Time Periods 5 :30 75 Pm Adjust the heating setpoint for Evening. (35 - 99 ) o COOL 73 HEAT o Evening Press MODE I I :30 Pm Start Adjust the start time for Night. Night Press MODE I I :30 Pm Adjust the cooling setpoint for Night.
Advanced Setup MODE PROGRAM Press the Mode button. While holding the Mode, press the Program button to enter Setup screens. Adjust the time of day clock. I2:00 AM NOTE: Each step # is located at the top right corner of the display for easy reference. Setup I Tip: To change hours quickly, press and hold the fan button in and then press the up or down buttons. Press Setup On Select residential Heat Pump, On or Off.
Advanced Setup 88 Adjust the deadband from 1 - 6 degrees. 8If Adjust the minimum difference between cooling & heating setpoints. (0 - 6 ) Select the cycles per hour limit. d=cycles per hour limit defeated. d1=d + defeat 5 min. Compressor lockout. (d, d1, 2 - 6) 2 2 6 Setup 5 Press MODE Setup 6 COOL HEAT Press Setup 7 Cy MODE Press MODE C Select thermostat operation in degrees Fahrenheit or Centigrade.
Advanced Setup Advanced Setup Table Step # 1 2 3 4 6 7 8 9 Description Time of day clock set Heat Pump Reversing Valve polarity Electric Heat Deadband Forced minimum difference heat/cool Cycles per hour Fahrenheit or Centigrade Range Factory Default 24 hour Off/On O/B Off / On 1-6 0-6 d, d1, 2 - 6 F/C 12:00 Am Off O Off 2 2 6 F Accessed and configured through the Set Clock button.
About Advanced Features & Operation MEMORY BACKUP - In the event of a power loss, the thermostat will retain the stored program settings without external power or batteries. 2 STAGE OPERATION - The 2nd Stage of heat is turned on when (1) the 1st Stage has been on for a minimum of two minutes, and (2) the temperature spread from the setpoint is equal to or greater than: the setpoint plus the deadband, plus 2 degrees.
About Advanced Features & Operation EMERGENCY HEAT - Is a feature available to Heat Pump installations. To turn on Emergency Heat press in the Fan button. While holding the Fan button press the Up button for 2 seconds. The Cool setpoint display will read ‘EH’. : 12:00 Press for Emergency Heat 73 Am eh o 74 HEAT o FAN During Emergency Heat the thermostat will turn on the fan and the 2nd stage of heat, when there is a demand for heat, locking out the 1st stage compressor.
About Advanced Features & Operation KEYPAD LOCK - To prevent unauthorized use of the thermostat, the front panel buttons may be disabled. To disable, or ‘lock’ the keypad, press and hold in the Mode button. While holding the Mode button in, press the Up and Down buttons in together. The Locked icon will appear on the display. : 12:00 65 Press all 3 for Keypad Lockout MODE Pm Locked 85 COOL 55 HEAT o To unlock the buttons, again press and hold the Mode button.
About Advanced Features & Operation DUAL SETPOINT BEHAVIOR - The adjustable setpoint range is: 35 - 99 degrees in Fahrenheit and 7 - 35 degrees in Centigrade. When in the modes Heat or Cool, this adjustable range is unhampered. When adjusting any Auto mode, including programming 4 Time periods, the thermostat will not allow the Heat setpoint to get closer to the Cool setpoint than the value programmed as the minimum difference in step # 6, page 12.
Warranty Five-Year Warranty - This Product is warranted to be free from defects in material and workmanship.