Installation Instructions

INSTALLATION
1. WARNING
Toavoidreorelectricalshock,turnoffpoweratcircuit
breakerorfuse.Testthatthepowerisoffbeforewir-
ing.
2. MOUNT THE SWITCH BOX
For 2-Rocker Switch: Install a 3½" deep single-gang
switchboxora2"deepdouble-gangswitchbox.
For 3-Rocker Switch:Installa2½"deepdouble-gang
switchboxwithasingledeviceadapterplate.
3. ATTACH POWER CABLE
Clampwiringtoswitchboxandunitusingappropriate
clamp.Provide6"leadsinsideboxandfanforeasier
wiring.
4. CONNECT WIRING
Generalinstructionsforallcongurations:
Makesureboththeswitchboxandtheapplianceare
properlygrounded.
Makesuregroundwireissecurelyfastenedtocontrol's
groundscrew.Tightengroundscrew14to16-in.lbs.
torque.
Removeinsulationperstripgaugeoncontrol(approx.
5/8").Useproperwirenutsizesfornumberandsizeof
wires.
Forpush-interminals:Use#14-AWGsolidcopperwire
only.
Forscrewterminals:Use#12or#14-AWGsolidcop-
perwireonly.Tightenscrewterminals14to16-in.lbs.
torque.
Choose 4A., 4B. or 4C
4A.Whenusing2-Rockeror3-RockerSwitchtoturn
anapplianceON&OFF:
Make electrical connections following appropriate
diagram.
(over)
WARNING
Topreventseriousinjuryfromelectricalshockordamage
toelectricalcomponents-DO NOT WIRE HOT!
Eachindividualrockerswitchonthiscontrolisratedat15
AMPS,@120VAC.Thetotalloadonthiscontrolmust
notexceed20AMPS,@120VAC.
Warrantyisvoidifmiswired.
WARNING
ALL ELECTRICAL WORK MUST BE DONE IN
ACCORDANCEWITHLOCALCODES,ORDINANCES,
ORNATIONALELECTRICALCODEASAPPLICABLE.
FOR SAFETY, THIS PRODUCT MUST BE INSTALLED IN
A GROUNDED SWITCH BOX.IFYOUAREUNFAMILIAR
WITH METHODS OF INSTALLING ELECTRICAL
WIRING, SECURE THE SERVICES OF A QUALIFIED
ELECTRICIAN.
Turnoffpowerandlockoutservicepanelbeforeinstalling
orwiringthisproduct.
Usethiscontrolonlywithcopperorcopper-cladwire.Do
notusealuminumwirewiththisdevice.
2-ROCKER & 3-ROCKER SWITCHES
3-ROCKERSWITCH
2-ROCKERSWITCH
STEP 4A
NOTE: Iftheswitchhasnotbeenwiredproperlyandwiresneed
tobemoved,proceedasfollows:
WARNING: Toavoidreorelectricalshock,turnoffpowerat
circuitbreakerorfuse.Testthatthepowerisoff
beforewiring.
1.Each wireopening hasa
releaseslot.
2. Push a small nail or
screwdriver into release
slotwhilegentlyremoving
wire.
3. DO NOT pull any wire
out of the switch without
using the release slot.
Theswitchmaybecome
damaged.
RELEASESLOT
WIREOPENING
C O M
B L A C K
W H I T E
G R O U N D
G R D
B L A C K
W H I T E
G R O U N D
1 2 0 V A C
L I N E I N
L O A D
1
L O A D
2
S I N G L E - G A N G
S W I T C H B O X
A P P L I A N C E
R E D
CO M
GR D
BL A CK
WH I TE
DO U BLE - GANG SWI T CH B O X
(w i th s ingl e de v ice a dap t er p l ate )
AP P LIA N CE
GR O UND
12 0 VA C
LI N E I N
BL A CK
WH I TE
BL A CK
WH I TE
GR O UND
LO A D
1
LO A D
2
LO A D
3
RE D

Summary of content (2 pages)