Spec Sheet

14 3/8"
6"
10"
21"
10"
21"
14 3/8"
32 3/16"
25 13/16"
29"
22 13/16"
21" 24 3/16"
Top Supply Option
91 LBS.
THE B120DHV
DELIVERS DEHUMIDIFIED
VENTILATION AND FEATURES A
HORIZONTAL CONFIGURATION TO
FIT ANY ATTIC, BASEMENT OR
CRAWL SPACE INSTALLATION.
Front Side Back
PERFORMANCE
ELECTRICAL
Power 840 watts @ 80°F and 60% RH
Supply Voltage 115 volt – 1 phase – 60 Hz
Current Draw 7.3 amps
Power Cord 9’, 115 VAC, Ground
Circuit Requirement 15 Amps
SPECIFICATIONS
Duct Connections 6” Round Inlet, 10” Round Inlet, 10” Round Outlet
Drain Connection 3/4” Threaded Female NPT
Refrigerant R410A, 1 lb. 10 oz.
Unit Dimensions 14.375”W x 21”H x 32.1875”D
Unit Weight 91 lbs.
SHIPPING
Shipping Dimensions 18.5”W x 23.5”H x 40”D
Shipping Weight 101 lbs.
Pallet Quantity 4 per pallet
Shipping Options LTL
FEATURES
+ Features a horizontal conguration with
optional vertical discharge
+ Designed for quiet operation
+ Engineered for low temperature operation
providing comfort year round
+ Use of DEH 3000/R digital control for
outdoor air ventilation and humidity control
+ Superior MERV-13 ltration to improve
indoor air quality
+ Ducting option for fresh outdoor air
ventilation
+ Push button reset for transformer
protection
Plug Type B
(USA, MEX, CAN, JPN)
Water Removal 121 Pints / 15.125 Gallons
Efciency 6.1Pints/kWh
Energy Factor 2.95 L/kWh
Blower 350 CFM @ 0.0” WG
285 CFM @ 0.2” WG
210 CFM @ 0.4” WG
Operating Temperature 49°F Min., 95°F Max.
Sizing Up to 3,000 Sq. Ft. / 30,000 Cu. Ft.
For additional information - visit www.broan-nutone.com.
TS-1215
09/21 Rev. B
B120DHV
Project:
Location:
Qty:
Architect:
Engineer:
Contractor:
Submitted by: Date:
Remarks:

Summary of content (2 pages)