Model 4000/4001 Important Information.............................................2 Safety Information..................................................3 Component Identification.......................................3 Specifications.........................................................4 Electrical Requirements.........................................4 Document # 100087 RevC Installation..............................................................5 Operation.........................................
IMPORTANT INFORMATION General The Model 4000/4001 Brewer Basic Examination Table is designed to provide positioning and support of patients during general examinations conducted by qualified medical professionals. Read and understand all safety information, operating instructions, and maintenance requirements contained in this manual prior to operating the table. Become familiar with all of the table functions before using it.
SAFETY INFORMATION Safety Information The primary concern of The Brewer Company is that the equipment is operated and maintained with the safety of the patient and healthcare staff in mind. To ensure safe and reliable operation: • Read and understand all instructions in this manual before attempting to install or operate the unit. • Ensure that appropriate personnel are informed on the manual contents. This is the responsibility of the purchaser.
SPECIFICATIONS Weight of Table......................................................190 lbs. (With carton and skid)...........................................235 lbs. Table Weight Capacity...........................................325 lbs. Stirrup Extension (maximum):.................................. 16 in. Stirrup Lateral Positions.......................4 Lateral Positions Leg Extension (maximum)........................................ 15 in. Dimensions: Upholstered Top.....................28.0 in.
INSTALLATION Overview Perform the following sequence in order when setting up the table: - Unpacking Leveling the Table Installing the Paper Rod NOTE: Save all packaging in case re-shipment is required. 2. Unbolt the table from the shipping pallet by removing the 4 bolt screws from the pallet with a 1/2” socket wrench and remove the shipping bracket. See Figure 3. Unpacking RECOMMENDED TOOLS: - 1. Carefully remove outer carton by removing the staples along the bottom of the carton and lift off table.
INSTALLATION (CONTINUED) Leveling the Table (Figure 4) A leveling screw pad is located at each corner under the table’s base. Adjust the four leveling pads, by turning them up or down, to achieve a solid, level installation. Installing the Paper Rod (Figure 5) A dowel rod for supporting a paper roll is shipped with each table. 1. Slide the dowel rod through the paper roll. 2. Place one end of the dowel rod on one of the paper roll brackets, located on the rear side of the table’s back section. 3.
OPERATION General Back Section (Figure 6) 1. Press and hold the release handle, lift back section upward to raise. Releasing the handle will automatically lock the table in the desired position. DANGER Do not use this table in an explosive or oxygenrich atmosphere. To do so will result in an explosion or fire. 2. While actuating the release handle upwards, push down on the back section to lower it. Back Section Release Handle Figure 6.
OPERATION (CONTINUED) Footstep (Figure 7) 1. Place hand into opening in front of step and gently lift while pulling step out to desired position. WARNING 2. To retract step to stowed position, gently lift while pushing step fully back into cabinet. Extend the footstep far enough to allow enough surface area for patients to safely stand on the step without risk of injury. WARNING Do not place more than 325 lbs. on step or table will be unstable. WARNING The footstep extends 11” from the table.
OPERATION (CONTINUED) Stirrups (Figure 8) Retracting the stirrup to the storage position: 1. Rotate stirrup to the first lateral position (parallel to the table). WARNING Failure to engage the stirrup lateral locking mechanism could allow patient to lose balance resulting in personal injury to patient. Extending the stirrup to functional position: 1. Gently lift and pull straight out of the table to the desired extension. Extend the stirrup to the functional position. 2.
OPERATION (CONTINUED) Leg Extension (Figure 9) Horizontal Positioning WARNING The leg extension is not intended to be extended during entry onto or exit off of the table. The leg extension is not intended to be used as a seat. Failure to heed this warning could result in serious personal injury. 1. Pull leg extension out to the desired position. The upholstered pad on the leg extension will extend along with the leg extension. 2.
OPERATION (CONTINUED) Patient Positioning (Figure 10) The table is designed to accommodate the following examination positions: • Full Flat Table Position • Chair Position • Lithotomy (Pelvic) Position Chair Position Lithotomy (Pelvic) Position Full Flat Table Position Figure 10.
OPERATION (CONTINUED) Pelvic Lift - Model 4001 Only (Figure 11) Drawer Warmer - Model 4001 Only (Figure 11) Raising the seat section to the Pelvic Lift Position: CAUTION 1. Raise the front edge of the seat section. 2. Rotate the pelvic tilt support bar upward to its full upright position. 3. Lower the seat section onto the pelvic tilt support bar. Lowering the seat section back to the Normal Position: 1. Slightly raise the front edge of the seat section. 2.
MAINTENANCE Preventative Maintenance • Periodically inspect the electrical cord to ensure it is free of cuts or damage. Painted Metal Surfaces Wipe all painted metal surfaces with a clean cloth at least once a week. • Inspect the mechanical functions to ensure satisfactory operation. • Check fasteners to make sure they are present and secured tightly.
MAINTENANCE (CONTINUED) Fuse Replacement (Figure 12) WARNING Replace fuse with same type and rating only (P/N 100091, 3A, 250V). 1. Remove bottom rear drawer to access fuse assembly. To remove drawer, pull locking tabs to left while pulling drawer outward. See Figure 12. 2. Push fuse in with flat blade screwdriver, turn counterclockwise and pull outward. See Figure 13. 3. Fully insert new fuse of same type and rating. 4. Turn fuse clockwise while pushing inward. 5.
OPTIONS, ACCESSORIES, AND COMMON SERVICE PARTS Listed below are the accessories which are authorized for use with this table. Description Order No. Use/Restrictions Replacement Upholstery 4115-XX Intended Use - Replacement top with hardware for 4000 and 4001, examination tables in 18 standard colors. Special Upholstery 4115-SP Intended Use-Allows the purchase of specialty vinyls in different colors with the model 4000 and 4001 examination table.
LIMITED WARRANTY The Brewer Company GENERAL TERMS AND CONDITIONS Warranty: The Brewer Company warrants its Basic Exam Tables to be free from defects in parts and workmanship under normal use and service for a period of three (3) years from date of shipment. The Brewer Company will not be responsible for any Product failure due to abuse, misuse, modification or improper use or for any use which exceeds the published capacity of the Product.