6100 User Guide

27 User Manual
Adaptive Recovery Mode (ARM
)
Adaptive Recovery Mode is a feature enabled/disabled in the Installer Settings (See Installer Guide).
If enabled, the feature is automatically present while in programmable mode.
Adaptive Recovery Mode tries to reach your desired heating or cooling temperature at the time you have set in
your current program schedule, after a setback period. For example, if you set your heat down to 62° at night
and have a set point of 70° scheduled for 7:00 AM, the thermostat may turn on your heating system early in
order achieve a temperature of 70° by 7:00 AM.
This feature does not operate when the thermostat is in HOLD mode, if the program is temporarily overridden or
if emergency heat is selected on a multistage heat pump system.
Circulating Fan Mode
Circulating Fan Mode is selected by touching the FAN
TouchPad
until CIRC appears in the display.
Fan operates as required by heating and cooling system (just like
AUTO mode). When heating or cooling is not active, fan will run
as needed to ensure a 35% minimum run time.