Installation Sheet

8
Powder Coated & Stainless Steel Restroom Partitions, Floor-Mounted with Overhead Brace Series 400 Installation
3/21/2018 Bradley • HDWT-INSTR-009 Rev K; ECN 17-14-007
4
Stirrup Brackets to Pilaster (Standard)
Refer to the submittal drawing to locate the split
dimension and layout location of each marked pilaster.
Measure 17-7/16 (443mm) and 63-7/16" (1611mm) down from
the top of each pilaster and place a mark on the pilaster split
centerline.
A
Split
Split
17-7/16"
(443mm)
63-7/16"
(1611mm)
Place stirrup brackets at each established level line. Center
the bracket opening on the pilaster split centerline. Using the
bracket as a template, mark the hole locations on the pilaster.
Remove the bracket and drill a Ø3/16" pilot hole (through
inside face of pilaster only) at each location.
B
Secure the stirrup brackets to the pilasters using the #14 x 5/8"
screws provided.
C
4a
Continuous Brackets to Pilaster (Optional)
Refer to the submittal drawing to locate the split
dimension and layout location of each marked pilaster.
Measure down from the top of the pilaster and
place a mark on the pilaster split centerline
at dimensions "A" and "B" for the respective
bracket (see table at left).
A
Secure the continuous bracket to the
pilasters using the #14 x 5/8" stainless
screws provided.
C
Split
Split
"A"
"B"
Dim. "A" Dim. "B"
Stainless
Steel
Bracket
11-15/16"
(302mm)
69-15/16"
(1749mm)
Aluminum
Bracket
11-11/16"
(297mm)
69-3/16"
(1749mm)
Place the continuous bracket between each
established level line. Center the bracket
opening on the pilaster split centerline. Using
the bracket as a template, mark the hole
locations on the pilaster. Remove the bracket
and drill a Ø3/16" pilot hole (through inside
face of pilaster only) at each location.
B
Brackets are used as templates but since the hole patterns
may be different, the brackets may not be interchangeable.
Continuous stainless steel bracket shown.
Pilaster shown is for reference only. Actual pilaster varies
depending on application.
Pilaster shown is for reference only. Actual
pilaster varies depending on application.
C
L
C
L
C
L