Installation Sheet

14
Powder Coated & Stainless Steel Restroom Partitions, Floor-Mounted with Overhead Brace Series 400 Installation
3/21/2018 Bradley • HDWT-INSTR-009 Rev K; ECN 17-14-007
6d
Wall-Hung Pilasters (58" or 69-9/16") - Stirrup Brackets (Optional)
To establish level line, from the highest point in the room, measure 12" (305mm) from the floor. Use a level to transfer
this mark to the pilaster plumb line.
See Step 2 for instructions on mounting the stirrup brackets to a wall.
Wall
Specified Dimension
(Standard Gap 1")
12"
(305mm)
Pilaster
Plumb Line
Floor
Pilasters at Wall Pilasters at Pilasters
Specified
Dimension
See Step 4 for instructions on mounting the stirrup brackets to a pilaster.
Floor
Pilasters shown in two different lengths for visual reference.
69-9/16" (1767mm)
Pilaster
58" (1473mm)
Pilaster
Slide the wall-hung pilaster into the stirrup brackets
and align with the established level line. Refer to
the submittal drawing and adjust to meet the
specified dimension.
A
Using the stirrup brackets as a template, drill
Ø3/16" holes through the pilaster at each bracket
hole. Secure the pilaster to the bracket using the
#14 x 5/8" screws provided.
B
Slide the wall-hung pilaster into the stirrup brackets
and align with the established level line. Refer to
the submittal drawing and adjust to meet the
specified dimension.
A
Using the stirrup brackets as a template, drill
Ø3/16" holes through the pilaster at each bracket
hole. Secure the pilaster to the bracket using the
#14 x 5/8" screws provided.
B
12"
(305mm)
C
L
69-9/16" (1767mm)
Pilaster
58" (1473mm)
Pilaster