Installation / Operation Instruction Manual

30
MAINTENANCE
The following maintenance should be performed by a qualified service
technician at the minimum periodic intervals suggested below. In some
installations, the maintenance interval may be more frequent depending on the
amount of use and the operating conditions of the water heater. Regular
inspection and maintenance of the water heater and vent-air intake system will
help to ensure safe and reliable operation.
1. Annually check the operation of the thermostat.
2. The flow of combustion and ventilation air must NOT be restricted. Clear
the combustion air openings of any dirt, dust, or other restrictions.
3. At all times keep the water heater area clear and free from combustible
materials, gasoline and other flammable vapors and liquids.
4. Bi-annually conduct a visual check of the main and pilot burner flames to
determine that they are burning properly. See Burner Flame Check (page
29). If sooting or other burner anomalies are evident, shut down the water
heater by turning off the gas per the instructions listed in this manual or as
listed on the water heater.
IMPORTANT
The water heater should be inspected at a minimum annually by a
qualified service technician for damaged components and/or joints
not sealed. DO NOT operate this water heater if any part is found
damaged or if any joint is found not sealed.