Service Manual
20
ECO Defender Series
Resettable Thermal Switch Testing and Replacement (cont.)
Step 1.
Rotate gas control knob to the
“OFF” position.
Remove outer jacket door.
Disconnect wire leads from
resettable thermal switch.
Remove (2) ¼” hex drive screws
from the manifold mount.
Remove resettable thermal switch from
manifold mount (Phillips screw driver).
Place new resettable thermal switch in place. Be sure contact surface
of resettable thermal switch and manifold mount are free of any debris.
Secure resettable thermal switch into place using screws from step 6.
DO NOT OVER TIGHTEN SCREWS.
Reconnect wire leads from gas valve and thermopile to resettable
thermal switch.
Step 2.
Step 3.
Step 4.
Step 5.
Step 6.
Step 7.
Note: Wire terminations are interchangeable with either resettable
thermal switch connection.
Step 8.
Step 9.
Replace outer jacket door.
To resume operation, follow the instructions located on the lighting
instruction label or the lighting instruction located in the installation and
operation manual.