Spec Sheet

NATURAL GAS
Ultra Low NOx Damper Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
Recovery efficiency ranging up to 78%
Model
Number
Approx.
Shipping
Weight
lbs.
A
Floor to
Flue
Conn.
in.
B
Jacket
Dia.
in.
Capacity Recovery at
90°F Rise*
URG1D30T6N
URG1D40S6N
URG1D40T6N
URG1D50T6N
U.S.
Gal.
30
40
40
50
Imp.
Gal.
25
33
33
42
Nat.
BTU/Hr.
Input
32,000
40,000
40,000
40,000
Nat.
U.S.
GPH
34
43
43
54
Nat.
Imp.
GPH
25
36
36
45
63
54
13
/16
63
9
/16
63
3
/8
120
151
138
164
16
20
18
20
F
Floor to
Water
Conn.
in.
57
1
/8
49
1
/8
57
1
/2
57
7
/8
C
Vent
Size
in.
3x4
3x4
3x4
3x4
E
Floor to
Gas
Conn.
in.
11
3
/4
11
3
/4
11
3
/4
11
3
/4
D
Floor to
T&P
Conn.
in.
49
7
/8
41
50
1
/8
49
7
/8
Model
Number
Approx.
Shipping
Weight
kg.
A
Floor to
Flue
Conn.
mm.
B
Jacket
Dia.
mm.
Capacity Recovery at
50°C Rise*
URG1D30T6N
URG1D40S6N
URG1D40T6N
URG1D50T6N
Liters
114
151
151
159
Nat.
kW
Input
9.4
11.7
11.7
11.7
58
74
76
89
220
280
288
337
0.65
0.62
0.62
0.60
0.65
0.62
0.62
0.60
1st Hour
Rating
(Gal.)
1st Hour
Rating
(Liters)
Energy
Factor
Energy
Factor
Nat.
Liters/
Hour
124
163
163
163
1600
1392
1614
1610
54
68
63
74
406
508
457
508
F
Floor to
Water
Conn.
mm.
1451
1248
1451
1470
G
Depth
in.
20
3
/4
24
3
/4
22
3
/4
24
3
/4
G
Depth
mm.
527
629
578
629
C
Vent
Size
mm.
76x102
76x102
76x102
76x102
E
Floor to
Gas
Conn.
mm.
298
298
298
298
D
Floor to
T&P
Conn.
mm.
1267
1041
1273
1267
Residential Atmospheric Vent Gas Water Heater
General:
Meets NAECA Requirements.
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3⁄4" NPT (19mm)
on 8" (203mm) centers. All Gas Connections are 1/2" (13mm).
All models design-certified by CSA International (formerly AGA/CGA), to meet ANSI standard Z-21.10.1 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing
heating system or component(s) previously used with a non-potable water heating appliance.
Available in Natural Gas only.
For 10 year models, change suffix from “6” to “10”.
*Based on manufacturer’s rated recovery efficiency.
Energy Factor and First Hour Rating is based on the
latest AHRI directory listings.
Printed in U.S.A.
1118-A-0815
©2015, Bradford White Corporation. All rights reserved.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931
Fax 215-641-1670 / Technical Support 800-334-3393
Fax 269-795-1089
Warranty 800-531-2111
Fax 269-795-1089
International: Telephone 215-641-9400
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100
Fax 905-238-0105 / www.bradfordwhite.com
C
A
F
E
D
B
G