Installation / Operation Instruction Manual

1 238-49754-00D 9/20
SUPPLEMENT VENTING INSTRUCTIONS FOR INSTALLATION AND OPERATION INSTRUCTION MANUALS FOR
THE FOLLOWING PRODUCT TYPES:
HIGH EFFICIENCY CONDENSING COMMERCIAL, COMMERCIAL POWER DIRECT VENT, LIGHT DUTY
COMMERCIAL POWER DIRECT VENT, LIGHT DUTY COMMERCIAL POWER VENT, RESIDENTIAL POWER DIRECT
VENT, RESIDENTIAL POWER VENT MODEL SERIES, ULTRA LOW NOx RESIDENTIAL POWER DIRECT VENT,
ULTRA LOW NOx LIGHT DUTY POWER DIRECT VENT, ULTRA LOW NOx RESIDENTIAL POWER VENT, ULTRA
LOW NOx LIGHT DUTY POWER VENT, HIGH PERFORMANCE SERIES POWER VENT, COMBI POWER VENT,
SOLAR POWER VENT GAS BACKUP.
INSTALLATION OF CENTROTHERM INNOFLUE® SINGLE WALL POLYPROPYLENE VENTING SYSTEMS
This supplement is for the installation of polypropylene single wall venting system manufactured by Centrotherm ECO
Systems, LLC. The Centrotherm venting system is a CSA approved alternative to the PVC, ABS, and CPVC venting
components for the High Efficiency Condensing Commercial, Commercial Power Direct Vent, Light Duty Commercial
Power Direct Vent, Light Duty Commercial Power Vent, Residential Power Direct Vent, Residential Power Vent Model
Series, Ultra Low NOx Residential Power Direct Vent, Ultra Low NOx Light Duty Power Direct Vent, Ultra Low NOx
Residential Power Vent, Ultra Low NOx Light Duty Power Vent, High Performance Series Power vent, Combi Power Vent,
Solar Power Vent Gas Backup Model Series.
The Centrotherm venting system components are ULC S636 approved and listed by a recognized agency and may be
installed in the U.S. and Canada. All components used must be from the same manufacturer and are designed for use
with the above noted products. The Centrotherm components may be purchased from plumbing supply distributors.
The vent size diameter and maximum vent lengths must be followed as detailed in the Installation and Operating
Instruction Manual that was supplied with the water heater. Thoroughly read and understand the venting section of the
instruction manual supplied with the water heater before proceeding with the following instructions in this supplement.
The vent terminals supplied with the water heater or the factory approved accessory vent terminal kits must be used
with this venting system.
WARNING
The venting system must be properly installed. Failure to properly install the vent system could result in property
damage, personal injury, or death.
DO NOT install damaged venting system components. If damage is evident then please contact the supplier where
the water heater or venting system components were purchased for replacement parts.
Use only the vent terminals provided or factory authorized terminals for venting this water heater.
The water heater requires its own separate venting system. Do not connect the exhaust vent into an existing vent pipe
or chimney.
All of the exhaust venting connections must be leak checked with a soap solution upon initial start-up of the water
heater. Any leaks must be repaired before continuing operation of the water heater.
Do not terminate the venting where noise from the exhaust or intake will be objectionable. This includes locations
close to or across from windows and doors. Avoid anchoring the vent and intake pipes directly to framed walls, floors,
or ceilings unless rubber isolation pipe hangers are used. This prevents any vibrations from being transmitted into the
living spaces.
Do not exceed the venting distances or the number of elbows listed in the instruction manual supplied with the water
heater. Exceeding the maximum venting distances may cause the water heater to malfunction or cause an unsafe
condition.
DO NOT operate this water heater until the venting installation is complete and the piping completed. Failure to
complete installation before operation can result in property damage, personal injury, or death.