User Manual
English | 21
Bosch Power Tools 1 609 92A 2MD | (5.9.16)
Technical Data
Noise/Vibration Information
Sound emission values determined according to EN 60745-2-17.
Typically the A-weighted noise levels of the product are: Sound pressure level 86 dB(A); Sound power level 97 dB(A). Uncer-
tainty K =3 dB.
Wear hearing protection!
The vibration level given in this information sheet has been
measured in accordance with a standardised test given in
EN 60745 and may be used to compare one tool with anoth-
er. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main ap-
plications of the tool. However if the tool is used for different
applications, with different accessories or insertion tools or is
poorly maintained, the vibration emission may differ. This
may significantly increase the exposure level over the total
working period.
An estimation of the level of exposure to vibration should also
take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may sig-
nificantly reduce the exposure level over the total working
period.
Identify additional safety measures to protect the operator
from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work pat-
terns.
Declaration of Conformity
We declare under our sole responsibility that the product de-
scribed under “Technical Data” is in conformity with all rele-
vant provisions of the directives 2009/125/EC (Regulation
1194/2012), 2011/65/EU, 2014/30/EU, 2006/42/EC in-
cluding their amendments and complies with the following
standards: EN 60745-1, EN 60745-2-17, EN 50581.
Technical file (2006/42/EC) at:
Robert Bosch Power Tools GmbH, PT/ETM9,
70538 Stuttgart, GERMANY
Robert Bosch Power Tools GmbH
70538 Stuttgart, GERMANY
Stuttgart, 01.01.2017
Assembly
Before any work on the machine itself, pull the mains
plug.
Inserting the Routing Motor into the Plunge
Base/Non-plunge Base (see figuresA–B)
– Open the clamping lever for the plunge base/non-plunge
base 22.
– Push the routing motor to the stop into the plunge
base/non-plunge base.
– When using the non-plunge base 3, press clamping lever
25 and slide the routing motor 1 up or down to the desired
position in the non-plunge base 3, until it, with the clamp-
ing lever 25 released, engages in one of the 3 notches 26.
Multifunction Router GOF 1600 CE GKF 1600 CE
Article number
3 601 F24 0.. 3 601 F24 0..
Rated power input
W16001600
No-load speed
min
-1
10000 – 25000 10000 – 25000
Speed preselection
Constant electronic control
Connection for dust extraction
Tool holder
mm
inch
8–12
¼–½
8–12
¼–½
Plunge depth (plunge base)
mm 76 –
Weight according to EPTA-Procedure 01:2014
kg 5.8 4.3
Protection class
/II /II
The values given are valid for a nominal voltage [U] of 230 V. For different voltages and models for specific countries, these values can vary.
GOF 1600 CE GKF 1600 CE
Vibration total values a
h
(triax vector sum) and uncertainty K determined
according to EN 60745:
a
h
K
m/s
2
m/s
2
=5.5
=1.5
=6.0
=1.5
Henk Becker
Executive Vice President
Engineering
Helmut Heinzelmann
Head of Product Certification
PT/ETM9
OBJ_BUCH-1178-006.book Page 21 Monday, September 5, 2016 8:53 AM