Quick Installation Guide

DSA E-Series (E2800 60-bay) Connection | en 23
Bosch Sicherheitssysteme GmbH Quick Installation Guide 2017.12 | V1 | DOC
Default Alternatively
Controller A
Controller B
LN K LN K
P1 P2
0b
0a
e0c
e0d
LN K LN K
P1 P2
0b
0a
e0c
e0d
1
23 4
5
6
1
23 4
5
6
LN K LN K
P1 P2
0b
0a
e0c e0d
LN K LN K
P1 P2
0b
0a
e0c e0d
1
23 4
5
6
1
23 4
5
6
1 Management port1 (Ethernet)
Note: Used as default.
2 Management port 2 (Ethernet)
Note: Reserved for maintenance
operations if the hardware contains a
second Ethernet port.
3 Channel3 / ControllerA and
Channel3 / ControllerB (iSCSI,
optical)
4 Channel4 / ControllerA and
Channel4 / ControllerB (iSCSI,
optical)
5 Channel5 / ControllerA and
Channel5 / ControllerB (iSCSI, RJ45
Base‑T)
6 Channel6 / ControllerA and
Channel6 / ControllerB (iSCSI, RJ45
Base‑T)
The Multipathing feature is enabled on dual controller units by default.
Dual controller units support 2different cabling options for the iSCSI ports.
Default: iSCSI, RJ45 Base‑T
Note:
Channel5 / ControllerB is the fallback of Channel5 / ControllerA and
Channel 6 / ControllerA is the fallback of Channel6 /. ControllerB
Alternatively: iSCSI, optical
Note:
Channel3 / ControllerB is the fallback of Channel3 / ControllerA and
Channel 4 / ControllerA is the fallback of Channel4 /. ControllerB