Quick Installation Guide

16 en | System setup - hardware DIVAR IP 7000 (2U)
2015.11 | V1 | DOC Quick Installation Guide Bosch Sicherheitssysteme GmbH
4.3.5 Installing the chassis in a Telco rack
Notice!
Do not use a two post "Telco" type rack.
!
Warning!
Stability hazard
Before sliding the unit out for servicing make sure that the rack stabilizing mechanism is in
place, or the rack is bolted to the floor. Failure to stabilize the rack can cause the rack to tip
over.
!
Warning!
Do not pick up the unit with the front handles. The handles are designed to pull the system
from a rack only.
Notice!
Mounting the chassis into the rack requires at least two people to support the chassis during
installation. Please follow safety recommendations printed on the rails.
Notice!
Figures are for illustrative purposes only. Always install chassis into racks from the bottom
up.
To install the chassis into a Telco type rack, use two L-shaped brackets on either side of the
chassis (four in total). First, determine how far the chassis will extend out the front of the
rack. Larger chassis should be positioned to balance the weight between front and back. If a
bezel is included on the chassis, remove it. Then attach the two front brackets to each side of
the chassis, then the two rear brackets positioned with just enough space to accommodate
the width of the Telco rack. Finish by sliding the chassis into the rack and tightening the
brackets to the rack.
4.4 Turning on the system
To turn on the system:
1. Plug the power cord from the power supply unit into a high-quality power strip that offers
protection from electrical noise and power surges. We recommended using an
uninterruptible power supply (UPS).
2. Press the power button on the control panel to turn on the system.