Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Certifications, approvals, listings, and safety
- Introduction
- System overview
- Installation checklist
- Control panel installation
- Power supply
- Telephone communications
- IP communications
- Keypads, keyswitches, keyfobs and transmitters
- Keypads
- B915 Basic Keypad
- B920 Two-line Alphanumeric Keypad
- B921C Two-line Capacitive Keypad with Inputs
- B930 ATM Style Alphanumeric Keypad
- B942 Touch Screen Keypad
- Shortcuts and custom functions
- Address settings
- Supervision
- Installation and control panel wiring (keypads)
- Sensor loops overview and wiring (B921C/B942/B942W only)
- Output wiring (B942/B942W only)
- Troubleshooting
- Keyswitches
- RADION keyfobs and Inovonics pendant transmitters
- Keypads
- On-board outputs
- Off-board outputs
- On-board points
- Off-board points
- Wireless modules
- Access control
- Program and test the control panel
- Control panel board overview
- System wiring diagrams
- Approved applications
- Keypad Installer menu
- [1] Program menu
- [1] Reporting > [1] Phone menu parameters
- [1] Reporting > [2] Network menu parameters
- [1] Reporting > [3] Routing menu parameters
- [1] Reporting > [4] Personal Note menu parameters
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS Parameters menu
- [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module)
- [3] RPS > [1] RPS Passcode menu parameters
- [3] RPS > [2] RPS Phone Number menu parameters
- [3] RPS > [3] RPS IP Address menu parameters
- [3] RPS > [4] RPS Port Number menu parameters
- [4] Area Options menu parameters
- [5] Keypad menu parameters
- [6] Users menu parameters
- [7] Points menu parameters
- [8] Disable Programming menu
- [2] Wireless menu
- [1] RF Point Menu> [1] Enroll Point RFID
- [1] RF Point Menu> [2] Replace Point RFID
- [1] RF Point Menu> [3] Remove Point RFID
- [2] RF Repeater Menu > [1] Add Repeater
- [2] RF Repeater Menu > [2] Replace Repeater
- [2] RF Repeater Menu > [3] Remove Repeater
- [3] RF Diagnostic Menu > [1] RF Points
- [3] RF Diagnostic Menu > [2] RF Repeater Menu
- [3] Diags menu
- [4] Serv Byp (Service Bypass) menu
- [5] Versions menu
- [6] Cloud menu
- [1] Program menu
- Specifications
- Appendix
- Back Page
B91x/B92x keypads use of IP Camera
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [3] Diags Menu > [4] IP Camera. The keypad shows one of the following statuses:
– Not Configured
– Not responding
– Bad Password
– Online
– Missing
3. When finished viewing the information, escape from the menu.
B93x/B94x keypads use of IP Camera
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [3] Diags Menu > [4] IP Camera. The keypad shows one of the following statuses:
– Not Configured
– Not responding
– Bad Password
– Online
– Missing
3. When finished viewing the information, escape from the menu.
[5] Cloud
B91x/B92x keypads use of Cloud (diagnostics)
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [3] Diags > [5] Cloud. The keypad shows the Cloud ID, which is also on a label on
the control panel.
3. Press [NEXT]. The keypad shows the Cloud configuration, which is one of the following:
– Not Available
– Enabled on Ethernet
– Enabled on Cellular
– Enabled on Ethernet and Cellular
4. Press [NEXT]. The keypad shows the Cloud Certificate status, which is one of the
following:
– Not Installed
– Certificate Valid
5. Press [NEXT]. The keypad shows the Cloud state, which is one of the following:
– Connected (and through which method)
– Not Ready
– Disconnected
– Not Available
– Trying to Connect
6. When finished viewing the information, escape from the menu.
B93x/B94x keypads use of Cloud (diagnostics)
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [3] Diags > [5] Cloud. The keypad shows the Cloud ID, which is also on a label on
the control panel.
3. Press
/[NEXT]. The keypad shows the Cloud configuration, which is one of the
following:
– Not Available
– Enabled on Ethernet
20.3.5
Control Panel Keypad Installer menu | en 143
Bosch Security Systems, Inc. Installation and System Reference Guide 2016.05 | 14 | F.01U.287.180