Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Certifications, approvals, listings, and safety
- Introduction
- System overview
- Installation checklist
- Control panel installation
- Power supply
- Telephone communications
- IP communications
- Keypads, keyswitches, keyfobs and transmitters
- Keypads
- B915 Basic Keypad
- B920 Two-line Alphanumeric Keypad
- B921C Two-line Capacitive Keypad with Inputs
- B930 ATM Style Alphanumeric Keypad
- B942 Touch Screen Keypad
- Shortcuts and custom functions
- Address settings
- Supervision
- Installation and control panel wiring (keypads)
- Sensor loops overview and wiring (B921C/B942/B942W only)
- Output wiring (B942/B942W only)
- Troubleshooting
- Keyswitches
- RADION keyfobs and Inovonics pendant transmitters
- Keypads
- On-board outputs
- Off-board outputs
- On-board points
- Off-board points
- Wireless modules
- Access control
- Program and test the control panel
- Control panel board overview
- System wiring diagrams
- Approved applications
- Keypad Installer menu
- [1] Program menu
- [1] Reporting > [1] Phone menu parameters
- [1] Reporting > [2] Network menu parameters
- [1] Reporting > [3] Routing menu parameters
- [1] Reporting > [4] Personal Note menu parameters
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS Parameters menu
- [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module)
- [3] RPS > [1] RPS Passcode menu parameters
- [3] RPS > [2] RPS Phone Number menu parameters
- [3] RPS > [3] RPS IP Address menu parameters
- [3] RPS > [4] RPS Port Number menu parameters
- [4] Area Options menu parameters
- [5] Keypad menu parameters
- [6] Users menu parameters
- [7] Points menu parameters
- [8] Disable Programming menu
- [2] Wireless menu
- [1] RF Point Menu> [1] Enroll Point RFID
- [1] RF Point Menu> [2] Replace Point RFID
- [1] RF Point Menu> [3] Remove Point RFID
- [2] RF Repeater Menu > [1] Add Repeater
- [2] RF Repeater Menu > [2] Replace Repeater
- [2] RF Repeater Menu > [3] Remove Repeater
- [3] RF Diagnostic Menu > [1] RF Points
- [3] RF Diagnostic Menu > [2] RF Repeater Menu
- [3] Diags menu
- [4] Serv Byp (Service Bypass) menu
- [5] Versions menu
- [6] Cloud menu
- [1] Program menu
- Specifications
- Appendix
- Back Page
B93x/B94x keypads configuration of Primary Destination Device
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [1] Reporting > [3] Routing. The keypad shows the primary device
for the selected route.
3. Use
/[PREV] or /[NEXT] to scroll though the list of routes and go to the route you
want to program.
4. Press [Edit] to edit the primary destination device for the selected route.
5. Use /[PREV] or /[NEXT] to scroll though the list of devices (for destination 1) and go
to the destination 1 option you want to select for the current device (for example, Phone
1).
6. To keep destination 1, escape from the menu. To change to a different destination (2, 3,
or 4), press [Edit Destination] and continue to Step 8.
7. Delete existing characters, if necessary, and then enter the new number.
8. Press [Save] to save the change, and then escape from the menu.
Backup Destination Device
Notice!
Keypads show and allow you to select the Backup Destination Device only after you select a
Primary Destination Device.
B91x/B92x keypads configuration of Backup Destination Device
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [1] Reporting > [3] Routing. The keypad toggles between showing
the current primary and backup setting for the selected route.
3. Use [PREV] or [NEXT] to scroll though the list of route and go to the route you want to
program.
4. Press [ENTER] to edit the route.
5. Press [NEXT] to go to the option to edit the backup route.
6. Press [ENTER]. The keypad shows Set Route Device.
7. Use [PREV] or [NEXT] to scroll though the list of device (for destination 1) and go to the
destination 1 option you want to select for the current device (for example, Phone 1).
8. Press [ENTER] to select the device. The keypad shows Set route dest 1-4. To keep
destination 1, escape from the menu. To change to a different destination (2, 3, or 4),
continue to Step 9.
9. Delete the current number, and then enter the new number.
10. Press [ENTER] to save the change, and then escape from the menu.
B93x/B94x keypads configuration of Backup Destination Device
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [1] Reporting > [3] Routing. The keypad shows the primary device
for the selected route.
3. Use
/[PREV] or /[NEXT] to scroll though the list of routes and go to the route you
want to program.
4. Press [Backup] to edit the backup destination device for the selected route.
5. Use [PREV] or [NEXT] to scroll though the list of devices (for destination 1) and go to the
destination 1 option you want to select for the current device (for example, Phone 1).
Control Panel Keypad Installer menu | en 113
Bosch Security Systems, Inc. Installation and System Reference Guide 2016.05 | 14 | F.01U.287.180