Data Sheet

Power Requirements
Current draw (maximum) Idle 125 mA; Alarm 155 mA
Output (alarm) 1.3 A at 12 VDC
Output (auxiliary, continuous
power, and switched auxiliary
combined)
800 mA at 12 VDC nominal
Voltage (operating): 12 VDC nominal
Voltage (AC) CX4010 Plug-in Transformer (18
VAC 22 VA 60 Hz) or
ICP‑TR1822‑CAN Plug‑in
Transformer (110 VAC primary,
18 VAC 22 VA secondary)
Ordering information
B5512 Control Panel
The B5512 is available individually or in kits.
For kits, refer to Quick Selection Guide (B Series Kits)
on the Documents tab of the control panel’s Product
Page at us.boschsecurity.com.
Order number B5512
B5512E Control Panel
The B5512E is available only in kits.
For kits, refer to Quick Selection Guide (B Series Kits)
on the Documents tab of the control panel’s Product
Page at us.boschsecurity.com.
Order number B5512E
Accessories
B520 Auxiliary Power Supply Module
Provides auxiliary power to 12 VDC devices or to SDI2
modules.
Order number B520
B201 2-wire Powered Loop Module
The module provides a single powered initiating device
circuit. The module supports compatible 12 V 2-wire
smoke detectors. It also supports connecting burglary
devices to the control panel.
Order number B201
B208 Octo-input Module
Provides 8 programmable inputs.
Order number B208
B308 Octo-output Module
Provides 8 programmable relays.
Order number B308
RADION receiver SD
Receives RF signals from RADION transmitters,
repeaters, and glassbreaks. Operates at 433.42 MHz.
For use with compatible SDI2 bus control panels.
Order number B810
D122 Dual Battery Harness
Harness with circuit breaker. Connects two batteries
to a compatible control panel.
Order number D122
D122L Dual Battery Harness with Long Leads
Color-coded harness with circuit breaker and leads
measuring 89 cm (35 in.). Connects 12 V batteries to
compatible control panels.
Order number D122L
D126 Standby Battery (12 V, 7 Ah)
A rechargeable sealed lead‑acid power supply used as
a secondary power supply or in auxiliary or ancillary
functions.
Order number D126
D1218 Battery (12 V, 18 Ah)
A 12 V sealed lead‑acid battery for standby and
auxiliary power with two bolt‑fastened terminals.
Includes hardware for attaching battery leads or spade
connectors
Order number D1218
CX4010 Plug‑in Transformer
For use in North America. 110 VAC primary voltage
input. 18 VAC, 22 VA secondary input.
Order number CX4010
ICP‑TR1822‑CAN Plug‑in Transformer
For use in Canada. 110 VAC primary voltage input. 18
VAC, 22 VA secondary input.
Order number ICP-TR1822-CAN
B8103 Enclosure
White steel enclosure measuring 41 cm x 41 cm x 9 cm
(16 in. x 16 in. x 3.5 in.).
Order number B8103
D8103 Enclosure
Grey steel enclosure measuring 41 cm x 41 cm x 9 cm
(16 in. x 16 in. x 3.5 in.).
Order number D8103
D8108A Attack Resistant Enclosure
Grey steel enclosure measuring 41 cm x 41 cm x 9 cm
(16 in. x 16 in. x 3.5 in.). UL Listed. Includes a lock and
key set.
Order number D8108A
D8109 Fire Enclosure
Red steel enclosure measuring 40.6 cm x 40.6 cm x 8.9
cm (16 in. x 16 in. x 3.5 in). UL Listed. Includes a lock
and key set.
Order number D8109
B10 Medium Control Panel Enclosure
White, steel enclosure. Accepts an optional lock and
tamper switch. Measures 35.6 cm x 31.8 cm x 7.6 cm
(14 in x 12.5 in x 3 in).
Order number B10
7 | B5512 Control Panels